Form 44201440
16
Oct 2018
Hold the side of the angle gauge without label flush against the glass surface. Hold a level against the other side of
the angle gauge and find the desired installation angle of the heater. Verify that the level is vertical, adjust heater
angle if needed.
Note: If a heat shield is installed its location must match the heaters angle (see Section 21.0).
This process must be repeated for both ends of the heater.
INDOOR INSTALLATION
–
HANGING METHODS
When the heater is used for an Indoor Installation then the following hanging methods may be used.
The heater can be hung from the ceiling, secondary steel work, etc. using chains, threaded rods and other approved
hanging materials. All hanging materials must have a minimum working load of 115 lbs.
Any “S” hooks must be
crimped closed after installation.
Note:
When hanging the heater hanging materials which allow the heater to move the gas connection must be
established using an approved flexible gas hose of a minimum of 24
”
length.
Diagram below shows Horizontal mounting with chain.
Diagram below shows the possible chain methods to hang at different angles.
Notes: When suspending at 25 degrees if the heat shield is installed use the 30-degree location for the heat shield.
INDOOR / OUTDOOR RIGID HANGING BRACKETS
Fixed hanging methods which prevent the heater from swaying must be used for outdoor installations.
Below are the bracket kits which can be used for ceiling and wall mount for patio heaters installed indoors and
outdoors, with and without heat shields. The brackets provide for a range of lengths and approved mounting angles
of 15
0
, 30
0
, 45
0
and 60
0
.
44560350 KIT, BRACKET - WALL/CEILING 15"-22" CEILING - FOR USE WITH HEAT SHIELD (telescoping)
44560351 KIT, BRACKET - CEILING 22"-30" - FOR USE WITHOUT HEAT SHIELD (telescoping)
44560353 KIT, BRACKET - CEILING 10"
–
FIXED (for outdoor only horizontal ceiling mount with heat shield)