Shenzhen SUNSKY Technology Limited
20
or other information ;to avoid damage the recorder please don’t disconnect the USB cable when downloading or
uploading
。
Recorder LCD display
Computer display
Double click “Removable Disk””
,
users will see four folder “HQ”
、
“SQ”
、
“LQ”
、
“MP3”
(
as below
picture
:)
These folders was established by DVR system, users can do delete
、
copy
、
download operation
,
If
delete DVR system will rebuilt the deleted folder
;
Folder “HQ”
、
“SQ”
、
“LQ” use to save recording file
;
HQ and LINE IN record type recording file will automatically save in “HQ” folder
,
SQ and LQ record type
recording file will automatically save in “SQ” and “LQ” folder
。
Able to connect recorder with computer in a variety working status
,
If set password On must input the
correct password to connect computer
,
Charge the same
。
16. Charging:
When battery icon is empty, indicate battery capacity is low, recorder will soon be power off; Please charge
。
Charge Method: Firstly connect attached USB cable with charger, and plug the charger in an electric outlet;
then connect USB cable with recorder. When charging LCD battery icon will be flashing until battery capacity is
full.
17
、
Question Solution
●
When power on
,
LCD display incomplete or can not power on
This is because the frequent operation or misuse leads the program error
,
it can be recovered after
format
,
you should uploading the useful files to computer before format
,
In format process all the recorder files
will be deleted
。
●
When power on, insensitive button operation
When power on
,
please press the button more than 2 seconds to fully activate the recorder, then to
operate the other button
。