Sunshine Solar CSDC40 Manual Download Page 8

INPUT

Battery Input

(

Start battery / DC generator

)

12.5-15.8 VDC

12.8VDC (adjustable range 12.5V~13.5V with 10sec delay)

15.8VDC

15VDC

Input voltage

factory default is 11.7V, adjustable 11.5V-12.5V (wait for 5sec the unit will
continue to charge if the voltage is higher than 11.7V, if  lower than 11.7V
the unit will stop working. Unit Will shutdown if lower than 11V)

Solar Input

Input low voltage
shutdown

15-45V

(

open circuit voltage of solar panel

)

15VDC

15.5VDC

45VDC

44VDC

600W Max

Input voltage

Input low voltage shutdown

Input low voltage recovery

Input overvoltage shutdown

Input overvoltage recovery

Solar panel wattage

Input low voltage recovery

Input overvoltage shutdown

Input overvoltage recovery

Warranty

The Suppliers warranty provides free replacement cover for all defects in parts and workmanship
for a period of twelve months unless otherwise stated, from the date of purchase. The Suppliers
obligation in this respect is limited to replacing parts which have been promptly reported by the
Customer as having been in his opinion defective and are so found by the Supplier upon
inspection. This warranty is void in the event of improper installation, Customer modification or
neglect, natural disasters and does not extend to support posts and ancillary equipment. No
responsibility is assumed for incidental or consequential damage.  No responsibility is assumed
for damage caused by the use of any unauthorised components, misuse, natural disasters,
lightning, gale or stronger force winds.

Disposal

When the device has become unusable, dispose of it in accordance with
the appliance disposal regulations

OUTPUT

Output voltage

Output current

Battery type 

GEL 

AGM 

WET 

Lithium

Constant voltage
range 

14.2VDC  14.6VDC  14.4VDC

13.8VDC  13.8VDC  13.5VDC

12VDC(nominal voltage)

40A Max (10A/15A/20A/25A/30A/35A/40A adjustable)

Program

(Custom settings)

14.4VDC(12.6-
14.8V Manually
adjustable)

4: LiFePO4: 12.6V~14.8V,
5: Custom program: 13.8V~14.8V

Floating voltage
range 

N/A

10/15/20/25/30/35/40 (optional setup on LCD panel)

Three-stage type

50mA

Max.90%

Charging current

Charging mode

standby loss

Efficiency

4: LiFePO4:0V=OFF or 13.0V~
14.8V,
5: Custom program: 13.8VDC
(13V~14V Manually adjustable)

Summary of Contents for CSDC40

Page 1: ...12V Battery Solar to Battery Charger CSDC40 Intelli Charge www sunshinesolar co uk Sunshine Solar Ltd Unit 30 Ashwellthorpe Industrial Estate Ashwellthorpe Norwich Norfolk NR16 1ER tel 44 0 1508 4881...

Page 2: ...tely supervised to ensure that they can use the appliance safely Risk of electric shock Do not open the device if it has been connected to the AC power source FERATURES The DC to DC charger is purpose...

Page 3: ...DIMENSION WIRING INSTALLATION Alternator terminal Fuse Starter Battery Backup battery Fuse 12V Solar Panel Earth Chassis Optional 5 meters Remote control with LCD display Optional...

Page 4: ...age Bulk charge BUL Absorption voltage ABS Floating FUL No charging NO Indicates battery capacity bar it is displayed only when the battery is connected It is dynamically displayed when charging Indic...

Page 5: ...ESC NEXT button will step to the next menu level MENU SAVE button will save the setting Press the ESC NEXT button for 5 seconds to exit the menu Leaving more than 10 seconds without adjustment will a...

Page 6: ...very 02 12 8V 12 5V 13 5V with delay 10sec Charge current 03 40A 10A 15A 20A 25A 30A 35A 40A Battery type 04 Constant charge voltage 05 1 AGM CV14 6V FV13 8V 2 WET CV14 4V FV13 5V 3 GEL CV14 2V FV13 8...

Page 7: ...current If the Internal or external temperature maximum the unit will stop charging The unit will automatically restart when the temperature falls Note 1 Internal temp protection 65 External temp prot...

Page 8: ...ted by the Customer as having been in his opinion defective and are so found by the Supplier upon inspection This warranty is void in the event of improper installation Customer modification or neglec...