Sunshine Solar CSDC40 Manual Download Page 7

PV over voltage 

E4

Internal over temperature 

E5

external over temperature 

E6

Internal  External over
temperature 

E7

4. CHARGING TEST:

● 

When the ignition terminal is not enabled (no voltage on the ignition terminal), PV
has priority. Based on ambient light conditions the battery will be charged via the
PV in  relation to the units settings.

● 

When  the  ignition  terminal  is  enabled,  DC  has  priority with relation to the units
settings.  If  the  DC  fails  the  battery  is  automatically  transferred  to  the  PV.

● 

When the DC is restored, the battery is automatically switched back To DC.

Fan control:

ON: Internal temperature >45

 or Current >30% of the set charge current

OFF: Internal temperature<35

 and current <20% of the set charge current.

If  the  Internal  or  external  temperature  maximum  the  unit  will  stop  charging.  The
unit  will  automatically  restart  when  the  temperature  falls.

Note:  1.Internal temp. protection>65

;External temp. protection <55

2.External temp. protection >60

;Internal temp. protection<50

,

External compensation -3mv.

3.PV/DC protection and recover value find in below:

5 DATASHEET

Faulty 

Code 

Faulty 

Code

DC low voltage

E1 

Internal over temperature

warning

A1

DC over voltage

E2 

external over temperature

warning

A2

PV low voltage

E3 

Internal  External over

temperature warning

A3

OTHERS

Internal over-
temperature protection

BTS

Product size

temperature>65

  , 

the charger shut down; temperature<55

 

,

the battery recover to charge again

Temperature of battery > 60

 

  the charger shut down to protect the battery;

temperature of battery <50

  ,

the battery recover to charger again

Temperature compensation coefficient-3mV/

 

L*W*H=221.7*164.2*74mm

Summary of Contents for CSDC40

Page 1: ...12V Battery Solar to Battery Charger CSDC40 Intelli Charge www sunshinesolar co uk Sunshine Solar Ltd Unit 30 Ashwellthorpe Industrial Estate Ashwellthorpe Norwich Norfolk NR16 1ER tel 44 0 1508 4881...

Page 2: ...tely supervised to ensure that they can use the appliance safely Risk of electric shock Do not open the device if it has been connected to the AC power source FERATURES The DC to DC charger is purpose...

Page 3: ...DIMENSION WIRING INSTALLATION Alternator terminal Fuse Starter Battery Backup battery Fuse 12V Solar Panel Earth Chassis Optional 5 meters Remote control with LCD display Optional...

Page 4: ...age Bulk charge BUL Absorption voltage ABS Floating FUL No charging NO Indicates battery capacity bar it is displayed only when the battery is connected It is dynamically displayed when charging Indic...

Page 5: ...ESC NEXT button will step to the next menu level MENU SAVE button will save the setting Press the ESC NEXT button for 5 seconds to exit the menu Leaving more than 10 seconds without adjustment will a...

Page 6: ...very 02 12 8V 12 5V 13 5V with delay 10sec Charge current 03 40A 10A 15A 20A 25A 30A 35A 40A Battery type 04 Constant charge voltage 05 1 AGM CV14 6V FV13 8V 2 WET CV14 4V FV13 5V 3 GEL CV14 2V FV13 8...

Page 7: ...current If the Internal or external temperature maximum the unit will stop charging The unit will automatically restart when the temperature falls Note 1 Internal temp protection 65 External temp prot...

Page 8: ...ted by the Customer as having been in his opinion defective and are so found by the Supplier upon inspection This warranty is void in the event of improper installation Customer modification or neglec...

Reviews: