Danger of death from electric shock! 

 

Solar modules generate electricity as soon as they are exposed to light. One module on its own is below the safety 

extra low volt level, but multiple modules connected in series (summing the voltage) or in parallel (summing the 

current) represent a danger. The following points must be observed when handling the solar modules to avoid the 

risk of fire, sparking and fatal electric shock.   

● 

Do not insert electrically conducting parts into the plugs or sockets!   

● 

Do not fit solar modules and wiring with wet plugs and sockets!   

  Exercise utmost caution when carrying out work on wiring and safety equipment (use insulated tools,   

insulated gloves, etc.)!   

  Do not use damaged modules! Do not dismantle modules! Do not mark on the rear of the module using 

sharp objects!   

  Exercise utmost caution when working on wiring and the inverter. Be sure carefully to follow manufacture’s 

installation instructions! 

       

  Artificially concentrated sunlight shall not be directed on the modules or panels! 

15

Danger of death from arcing

!  

Modules generate direct current when light shines on them. An arc may be produced when connections are 

separated. We therefore recommend covering modules with a lightproof cloth during installation. When breaking a 

connected string of modules (e.g. when disconnecting the DC line from the inverter under load), a lethally strong arc 

can occur:   

● 

Never disconnect the solar generator from the inverter while the inverter is connected to the mains 

grid—remove the fuse from the AC side on the inverter first! 

 

● 

Ensure cable connections in perfect condition (no splitting, soiling or other contamination)! 

 

 

Remark: all sizes are measured in mm; and tol/- 2 mm 

 

 

 

Summary of Contents for SR220-250P SERIES

Page 1: ...ules mainly include220W 225W 230W 235W 240W 245W 250W 1 Electrical Specification POLY Si series PHOTOVOLTAIC MODULE Model SR220 250P Number of cells pcs 60 Pmpp W 230 3 Voc V 38 0 3 Isc A 8 18 3 Vmpp...

Page 2: ...ight 50mm 1 97inch 2 Weight 21 5Kg 3 Cell 60 pcs 156mm 156mm solar cells 6 lines10 rows connected in series and array in matrix 4 Output cable 4mm2 cable with TUV certification with polarity mark wate...

Page 3: ...CLIMATE CONDITION Install the PV module in the following conditions Environment temperature 47 2 Operating temperature 40 to 85 Waterproof don t dip the modules into the water or continually explode...

Page 4: ...aximum load site specific live loads such as wind and snow should be taken into account The installation of project must be facing north in the southern hemisphere and facing south in the northern hem...

Page 5: ...diode to decrease the loss of energy the shadow will lead to the loss of output power 6 Grounding All module frames must be attached to an earth ground A qualified electrician must do the ground conn...

Page 6: ...t through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influence the conductive connec...

Page 7: ...urface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module The recommended stand off height is 115mm If other mounting means are employed this may...

Page 8: ...ed through the shaded area by the other modules When a bypass diode is wired in parallel with the series string the forced current will flow through the diode and bypass the shaded module thereby mini...

Page 9: ...ped or rubbed away when dry as this will cause micro scratch We recommend that the system be inspected at regular intervals 13 Checklists All fastenings are tight and secure and free of corrosion All...

Page 10: ...k on the rear of the module using sharp objects Exercise utmost caution when working on wiring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concent...

Reviews: