background image

 

 
 

and size of controls connected to the PV output.   

● 

Refer to section 690-8 of the NEC for an additional multiplying factor of 156 percent which may be 

applicable.   

● 

Installation should be in accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian 

Electrical Code, Part 1. 

2

Appearance character

 

 

No.   

Item   

Remark   

1   

Measurement   

length

1650mm (

64.961

inch)      width

992mm (39.1inch)      height

50mm (

1.97

inch)   

2   

Weight   

21.5Kg

 

3   

Cell   

60 pcs

156mm

×

156mm

solar cells

6 lines10 rows connected in series and array in matrix.   

4   

Output cable   

4mm

2

 cable with

 

TUV certification

with polarity mark, waterproof, length is 900mm 

。 

5   

Junction box   

With6 pcs connector

IP65

max system voltage 1000VDC

max current 12A , with TUV   

certification   

6   

Structure   

Front: high transparent toughened glass Front: high transmission toughened glass with 3.2 mm 

(1/8inch) height   

Back: Polyester   

Material 

EVA 

7   

Frame   

Anode oxidation. Aluminum alloy frame    Color: Silver   

8   

Insulated performance    50M

Ω

  

9   

Max system voltage   

1000V   

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SR220-250P SERIES

Page 1: ...ules mainly include220W 225W 230W 235W 240W 245W 250W 1 Electrical Specification POLY Si series PHOTOVOLTAIC MODULE Model SR220 250P Number of cells pcs 60 Pmpp W 230 3 Voc V 38 0 3 Isc A 8 18 3 Vmpp...

Page 2: ...ight 50mm 1 97inch 2 Weight 21 5Kg 3 Cell 60 pcs 156mm 156mm solar cells 6 lines10 rows connected in series and array in matrix 4 Output cable 4mm2 cable with TUV certification with polarity mark wate...

Page 3: ...CLIMATE CONDITION Install the PV module in the following conditions Environment temperature 47 2 Operating temperature 40 to 85 Waterproof don t dip the modules into the water or continually explode...

Page 4: ...aximum load site specific live loads such as wind and snow should be taken into account The installation of project must be facing north in the southern hemisphere and facing south in the northern hem...

Page 5: ...diode to decrease the loss of energy the shadow will lead to the loss of output power 6 Grounding All module frames must be attached to an earth ground A qualified electrician must do the ground conn...

Page 6: ...t through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influence the conductive connec...

Page 7: ...urface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module The recommended stand off height is 115mm If other mounting means are employed this may...

Page 8: ...ed through the shaded area by the other modules When a bypass diode is wired in parallel with the series string the forced current will flow through the diode and bypass the shaded module thereby mini...

Page 9: ...ped or rubbed away when dry as this will cause micro scratch We recommend that the system be inspected at regular intervals 13 Checklists All fastenings are tight and secure and free of corrosion All...

Page 10: ...k on the rear of the module using sharp objects Exercise utmost caution when working on wiring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concent...

Reviews: