In  the  northern  hemisphere,  modules  should  typically  face 

south,  and  in  the  southern  hemisphere,  modules  should 

typically  face  north;  For  detailed  information  on  the  best 

installation  angle,  please  refer  to  standard  solar  photovoltaic 

installation  guides  or  consult  a  reputable  solar  installer  or 

systems integrator. 

 

5.2 Mechanical installation 

Ensure  that  the  installation  method  and  supporting  system  of 

modules  is  strong  enough  to  make  the  modules  to  be  able  to 

withstand all the pre-established load conditions. The installer 

must  provide  the  guarantee.  The  installation  supporting 

system must be tested by the third-party organization with the 

analysis  ability  of  Static  Mechanical,  according  to  the  local 

national  or  international  standards  such  as  DIN1055  or 

equivalent standards. 

 

The  modules  mounting  structure  must  be  made  of  durable, 

corrosion-resistant  and  UV-resistant  material;  Modules  must 

be securely attached to the mounting structure; In regions with 

heavy  snowfall  in  winter,  select  higher  mounting  system.  So 

that  the  lowest  edge  of  the  modules  will  not  be  covered  by 

snow for long time. In addition, ensure that the lowest portion 

of  the  modules  is  placed  high  enough  so  that  it  will  not  be 

shaded by plants or trees, or damaged by flying sand; Because 

of  thermal  and  expansion  of  the  module  frames,  must  ensure 

that  the  minimum  distance  between  neighboring  frames  is 

10mm. 

 

5.2.1 Installation onto the curtain wall surface 

 

 

 

Cleaning  the  surface  carefully  and  spreading    the  structural 

adhesive on it along the longitudinal direction of the modules. 

Adhesive column  should roughly  follow the area of 1650mm 

long,  6~10mm  wide,  3~5mm  thick,  and  have  the  gap  of 

240mm  between  each  other.  Sticking  the  Lohmann 

double-sided tape of 1600mm long and 17mm wide onto each 

long  edge  of  the  modules  to  prevent  falling  off  before  the 

structural  adhesive  solidified.  In  order    to  achieve  the  best 

bonding  performance,  it  is  required  to    install  the  modules 

within  5  minutes  once  the  adhesive  is  applied  on  the  wall. 

Then pressing the modules gently against the surface (screws 

could  also  be  applied  as  auxiliary  method  as  per  customer’s 

requirements).  The  gap  between  each  module  shall  be  kept

 

around 1cm.   

 

5.2.2 Installation on the steel tile 

 

Spreading  the  structural  adhesive  onto  the  raised  part  of  tile 

Structural adhesive(8~10mm width)   

Summary of Contents for SPP M60S Series

Page 1: ...the right to make changes to its products or this manual without prior notice Sunport is not responsible for any damages caused by inappropriate installation use or maintenance of Sunport modules incl...

Page 2: ...Be cautious when setting the modules down onto a surface especially on the corner of the modules 4 2 Operating safety When unpacking the modules from the original package first remove the pallet lid a...

Page 3: ...e You must stop using the module if there is exposed combustible gas nearby In the event of a fire modules may continue to produce a dangerous DC voltage even if they have been disconnected from the i...

Page 4: ...lowest edge of the modules will not be covered by snow for long time In addition ensure that the lowest portion of the modules is placed high enough so that it will not be shaded by plants or trees or...

Page 5: ...by the coefficient of 1 25 On the basis of lowest local temperature combine with temperature coefficient of voltage in manual Voc can be calculated When modules are in series voltage to be added up w...

Page 6: ...tors are fully engaged and locked 5 3 4 Bypass diodes The junction boxes used with Sunport s modules contain bypass diodes wired in parallel with the PV cell strings In the case of partial hot spot th...

Page 7: ...The installation manual applicable module types are as follows The module types are subject to changes without prior notice due to continuous product innovation research and development XXX shows the...

Reviews: