12
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
UFO 3 INSTALLATION (2019.12.23) V1
Installation Conditions
I-beam
The yoke to I-beam for this HVLS fan is attached in our product. The yoke only can be
used within the width of 100-300 mm (B) and thickness of 20 mm I-beam. Within the
thickness of 14 mm (t), the yoke only need to use 1 yoke washer. The thickness of
14-20 mm (t), the yoke need 2 washers. We do NOT suggest to install the HVLS Fan on
the fabricated I-beam, please consult with structural engineer to make sure your
building is approved for fan installation.
I-beam shim