22
E08
Failure
of
the
controller
EEPROM.
24C02 is broken down or you forgot to install 24C02, change
the motor control board.
E09
Controller is in tilted position.
Machine is not placed on level
surface when it is powered on
Place machine on a level
surface, then start the
machine.
E10
Transient current protection
Check if the torsion of controller
is normal.
Adjust
the
torsion
regulator to normal value.
Check whether the motor is
short-circuited.
Change the motor.
Check
whether
treadmill’s
transmission part is stuck.
Eliminate the disturbance,
and
make
sure
the
treadmill runs smoothly.
E11
External AC over-voltage
Check whether the external AC voltage is higher than
270VAC, or if is unstable; if yes, stop using the product and
ask electrical engineers for help.
E13
Communicational
failure
between the meter and the
controller, and the meter cannot
receive the signal from the
drive.
Check
whether
the
wire
between the meter and the
controller is broken down.
Change the wire.
Check whether the socket is
plugged in well.
Re-plug the socket and
make sure it is reliable.
E14
External AC under-voltage
Check whether external AC voltage is lower than 160VAC or
if is unstable, if yes, stop using the product and ask the
electrical engineers for help.
NOTE: If you are unable to resolve an issue using the troubleshooting guide above, please
contact Customer Service at [email protected]
Version 1.1