We value your experience using Sunny Health and Fitness products. For assistance with parts or
troubleshooting, please contact us at [email protected] or 1-877-90SUNNY (877-
907-8669).
STEP 2:
Remove
Screw (No. 55)
and
Curve Washer
(No. 56)
from the
Tension Control Knob (No.
54)
using
Spanner (No. C)
.
Insert
Tension Control Wire (No. 54a)
into
Handlebar Post
(No. 42)
and pull it out from
the bottom.
Attach the
Tension Control Knob (No. 54)
to
Handlebar Post
(No. 42)
using 1
Screw (No.
55)
and 1
Curved
Washer (No. 56)
that were
removed. Tighten and secure with
Spanner
(No. C)
.
Note:
Please make sure the
Tension Control
Knob (No. 54)
is at the lowest resistance level
(level 1, all the way to the left) before you
connect the
Tension Control Wire (No. 54a)
.
Connect the
Trunk Wire (No. 53)
with the link
wire of
Sensor (No. 109)
and connect
Tension
Control Wire (No. 54a)
with
Tension Wire
(No. 60)
. Then, insert
Tension Control Wire
(No. 54a)
into the slot on metal bracket of
Tension Wire (No. 60).
Make sure the metal
fitting on
Tension Control Wire (No. 54a)
is
secured into the metal bracket.
Attach
Handlebar Post (No. 42)
to the
Main
Frame (No. 59)
using 3
Bolts (No. 41)
,
2
Bolts
(No. 40)
, 3
Spring Washers (No. 30)
,
2
Nylon
Nuts (No. 23)
and
7
Curved Washers (No.
34)
. Tighten and secure with
Allen Wrench
(No. A)
and
Spanner (No. C)