Pitched Roof Mount System
With Self-grounding Hardware
Pitched Roof Mount System
18
of
24
Splicing the rails together:
Where rail splicing is required, either the 2 bolt for the
3/8” rail
slot or the 4 bolt for the
1/4” rail slots can be used.
Shown is the 2 bolt
3/8”
rail slot version
which must be torqued to 15 ft. lbs.
Fig. 13
: The 2 bolt splice can be used to join rail section together
.
The 4 bolt version of the rail splice can also be used.
Torque on the
1/4” flange nuts is a
maximum of 7.5 ft. lbs.
Fig. 14
: A 4 bolt version of the self-grounding splice can
be installed to join rail sections together.