![SunMaxx Solar SmartMaxx-Pro-XL6D Installation Manual Download Page 23](http://html.mh-extra.com/html/sunmaxx-solar/smartmaxx-pro-xl6d/smartmaxx-pro-xl6d_installation-manual_1397961023.webp)
SunMaxx Solar | 5098 NY 206 Bainbridge NY 13733 | 1.877.786.6299 1.877.270.7875 fax | www.sunmaxxsolar.com
4. Settings
The necessary basic settings required for the control function are made in menu “5. Settings”.
The menu is closed by pressing “esc” or selecting “Exit settings”.
CAUTION
This does not under any circumstances replace the safety facilities to be provided
by the customer!
4.1 TMIN S (X)
CAUTION
The following pages contain generally valid descriptions for the settings. Enumera
-
tions may vary .
Enable/start temperature at sensor X:
If this value is exceeded at the applicable sensor X and the other conditions are also met, then the controller switches on the associated pump and/
or valve. If the temperature at the sensor drops below this value by 5°C, then the pump and/or the valve are switched off again.
Settings range : 0°C to 99 °C (32°F to 210 °F / Default setting: 20°C (68°F)
4.2 TMAX S (X)
Switch-off temperature at sensor X
If this value is exceeded at the applicable sensor X, the controller switches the associated pump and/or valve off. If the temperature falls below this
value again and the other conditions are also met, then the controller switches the pump and/or valve on again.
Settings range : 0°C to 99 °C (32°F to 210 °F / Default setting: 60°C (140°F)
DANGER
Temperature values which are set too high can lead to scalding or damage to the system. Scalding protection must be provided by
the customer!
4.3 TMAX SB
Switch-off temperature at pool sensor
If this value is exceeded at the applicable sensor, the controller switches the associated pump and/or valve off. If the temperature falls below this
value again and the other conditions are also met, then the controller switches the pump and/or valve on again.
Settings range : 0°C to 50 °C (32°F to 122°F / Default setting: 30°C (86°F)
DANGER
Temperature values which are set too high can lead to scalding or damage to the system. Scalding protection must be provided by
the customer!