INSTALLATION INSTRUCTIONS

 

 
 

Controller Mounting 

Find a suitable location to mount the control box. Remember all Pool equipment should be 
installed out of direct weather and no closer than 3 meters from the water’s edge.  Lift  up 
the two mounting tabs and use two appropriate screws to mount the control box to the wall, 
keeping  in  mind  that  the  power  cable  is  1.8m  long  and  should  be  plugged  directly  into  a 
general power outlet, not into an extension lead.  
 

Retro-Fit (Boosted) Systems  

If the SL6RR Controller is to be fitted to a Retro-Fit (Boosted) system the mains power cable 
is  to  be  plugged  into  the  same  power  source  as  the  filtration  pump.  This  is  to  prevent  the 
solar pump turning on and running dry. Ensure that the maximum current draw of the two 
pumps  does  not  exceed  the  switching  device  rating.  If  plugged  into  a  salt  chlorinator  or 
chemical dosing system, check the installation instructions and warranty for compliance.  

 
Pool Sensor 

For stand alone systems with separate suction and return the pool sensor must be fitted into 
the suction line of the solar boost pump, preferably in a position out of direct sunlight. For 
retro-fit systems the pool sensor must be fitted in the suction line of the main filter pump or 
between the outlet of the filter and before the take off Tee fitting for the solar boost pump. 
It  is  recommended  that  a  14.5mm  hole  be  drilled  in  the  PVC  pipe,  this  can  be  carried  out 
using a Dontek PD01 grinding drill or a small pilot hole can be drilled and a 14.0mm drill-bit 
used  spinning  in  a  counter  clockwise  direction  to  minimize  the  chance  of  shattering  pipe. 
Insert the grommet into the pipe and gently push in the black sensor barb. The green sensor 
plug is to be fitted to the centre plug socket. 

 
Transmitter 

Mount the transmitter box in an easy access location, normally next to the pipes running to 
the  roof  as  system  batteries  will  require  replacement  at  some  stage.  On  initial  installation 
remove the lid of the box and insert 4 AA alkaline batteries as marked on the battery holder, 
ensuring the batteries are  located correctly. The antenna should be pointing down towards 
the ground. 

Do Not

 

fit transmitter on the roof. 

 

Roof Sensor 

Roof sensors must be fitted into a small piece of solar collector or equivalent and attached to 
the roof.  The best location is within arm’s length of the gutters edge of the house or shed as 
long as the sensor end is not shaded and is on a roof of similar aspect of the main collector. 
It 

must  not

  be  fitted  on  top  of  the  solar  collector  or  fitted  to  high  points  on  the  roof  like 

Ridge Capping as false readings will be detected. 
Keep in mind that it is of the utmost importance to keep the roof sensor as short as possible 
as this will assist in the longevity of the sensor and controller in the event of electrical storm 
activity and power surges. Sensor cables 

must not be run parallel to power cables 

and 

run lengths should be less than 50m. Cable ties should be used to fasten the sensor cable to 
the  cold  water  inlet  pipe  making  sure  that  the  ties  are  approximately  10mm  from  PVC 
fittings.  Cable  ties  should  be  tightened  only  firm,  over  tightening  can  cause  breaks  in  the 
outer PVC if not careful. 

Any excess cable should be removed and re-fitted ensuring 

that the wire ends are tinned with solder. 

The sensor plug is to be fitted to the socket 

at the base of the Transmitter Box. 
 

Batteries 

Replacement AA batteries must be Alkaline quality or better, rechargeable batteries are not 
recommended. Do not mix battery types. 

Notes 

All excess cable must be removed; coils of cable are not permitted under any circumstances and 

must not

 

be  tied  to  240V  wiring.  If  the  cable  is  to  be  extended  with  non  genuine  cable  a  size  of  14/020  should  be 
used. 

Any  cable  joins  must  be  soldered  and

 

this  includes  where  the  cable  enters  the  terminal 

block at the case base

. Heat shrink is to be used over soldered joints to eliminate moisture ingress. If the 

cable end is to be refitted  to the  plug sockets then the polarity must be observed as incorrect polarity will 
show  an  error  as  stated  in  Fault  Diagnosis.  The  sensor  cable  with  the  thin  white  trace  is  the  positive  and 
should be fitted to the left hand cable entry when the screws are in a vertical position. 
Once cables have been correctly fitted the unit can be turned on. 
 

Clock: 

This  model  is  fitted  with  a  settable  24  hour  clock,  if  the  clock  needs  to  be  adjusted  then  hold  the  up  and 
down temperature buttons together until the display goes blank, then release the buttons. 
While the minutes light (M) is flashing rapidly, use the up or down buttons to set the minutes then press the 
select button. The (H) light will now be flashing rapidly so using the up or down buttons set the hours then 
press select. 
The SL6RR will now resume in summer mode (auto). 
 
NOTE: it is a 24 hour clock so 3 pm is 15 (add 12 after midday). 
 

Setting  the  clock  correctly  ensures  the  booster  pump  will  run  only  when  maximum  heating  is 
available, that is from 0800h (8 am) till 1800h (6 pm). 

It also ensures that the booster pump will not 

run at night to sample the pool water. Night time is indicated by a flashing AUTO light. 

 
Test Mode 

At the opposite side of the battery holder in the transmitter box there is a jumper pin marked J1. By 
moving the jumper from the RUN to the TEST position the transmitter will continuously send the roof 
temperature  to  the  SL6RR.  Use  the  select  button  on  the  SL6RR  to  read  the  ROOF  temperature,  a 
current roof temperature should be seen or a fault code. If a reception cannot be received make sure 
that  the  batteries  are  in  good  order  and  in  the  correct  way  and  that  the  code  switches  inside  the 
SL6RR  and  the  Transmitter  are  matched.  In  TEST  mode  every  second  transmission  will  cause  the 
SL6RR  controller  to  flash  all  the  LEDS  on  the  right  hand  side  to  scroll  upwards,  this  is  a  warning  to 
place the unit back into RUN mode as battery life is severely shortened while running in TEST mode. 
Due to the possibility of reception ghosting and electrical interference the Transmitter may be required 
to be moved to an alternative position, this may be as little as two meters and keep in mind that the 
roof  sensor  cable  may  be  extended  20  meters  if  required.  The  main  SL6RR  controller  should  be 
mounted away from other electrical appliances as far as possible to reduce the chance of interference. 
If the unit is to be installed in a metal shed there may be reception issues and the controller may need 
to be optioned with a remote antenna or moved outside. 
 

Fault Diagnosis 

In the event of a cable, sensor or transmitter fault, the display will indicate the type of fault as follows; 
 
ROOF SENSOR. 
A display of 99 indicates a broken or disconnected sensor cable or open circuit sensor. 
A display of 88 indicates wrong polarity connection or short-circuited cable or sensor. 
A display of 89 indicates a high sensor reading out of normal operating range. 
A display of 00 indicates no roof transmitter reception. 
 
POOL SENSOR 
A display of 77 indicates a broken or disconnected sensor cable. 
A display of 66 indicates wrong polarity or short-circuited sensor cable. 
A display of 67 indicates a sensor reading out of normal operating range. 

 
 

 
 