 5. Interface connections

1

 Power input jack.

2

 ZONE A temperature probe input jack.

3

 ZONE A signal output jack.

4

 ZONE B temperature probe input jack.

5

 ZONE B signal output jack.

1      2  3    4  5

 6. Indicator lights

1

  LED ON: Normal status (Temperature  

probe is working normally). 
LED OFF: Temperature Control line not  
connected or temperature control fail. 
LED SLOW FLASH: High temperature warning (reached preset value), ballast dimming 
down to decrease temperature. 
LED FAST FLASH: High temperature, exceeded preset value. Ballast turned off.

2

  LED LIGHT ON: Lamp on.   LED LIGHT OFF: Lamp off.

3

 Same as 1.

4

 Same as 2.

1 2 3 4

 7. Setting the time

 NOTE: Set controller time to your time zone. 

1

   Press  “

t

 

or

 

u

”, enter into “SYSTEM SETTING”.

2

   Press  “

t

 

or

 

u

”, to the parameter you want to set 

(Time for example: Hour / Minutes).

3

   Press  “

p

”, “Hour” value will increase, 

Press “

q

”, “Hour” value will decrease.

4

 Move cursor to set “M”, “D”, “Y”, “Hour”, “Time” or “Power” (W or%).

5

 Press “OK”. Time and Date setup is complete.

OPERATIONAL SETUP

 4. Keypad operation

Page up or page down

Right shift

Increase parameters

Reduce parameters

Confirm/save

Summary of Contents for Sun System 1

Page 1: ...TION MANUAL Vancouver WA Eureka CA Livermore CA Ontario CA Denver CO Detroit MI York PA Nashville TN Pompano Beach FL Vancouver B C Canada sunlightsupply com Control Sun System 1 Etelligent Ballasts with the same controller operating on 2 separate channels ...

Page 2: ...re connecting to controller please make sure the knob is rotated to RC position first 1 AC Adapter 120 240V 1 Patch Cord 2 Control Cables For connecting ballast to ballast No magnetic ring on cable Forconnectingballast tocontroller Magnetic rings on cable 2 Temperature Probes 2 Sun System One Controller accessories 3 Connection between ballast and controller ETELLIGENT CONTROLLER ZONE A up to 200 ...

Page 3: ...ease temperature LED FAST FLASH High temperature exceeded preset value Ballast turned off 2 LED LIGHT ON Lamp on LED LIGHT OFF Lamp off 3 Same as 1 4 Same as 2 1 2 3 4 7 Setting the time NOTE Set controller time to your time zone 1 Press t or u enter into SYSTEM SETTING 2 Press t or u to the parameter you want to set Time for example Hour Minutes 3 Press p Hour value will increase Press q Hour val...

Page 4: ...enter into the Time Setting 9 Setting the timer dimming 1 Press NEXT then OK to enter into ZONE A NOTE Follow this same setup for ZONE B 2 Press t or u choose o choose time and power percentage press p or q to þ 3 Then press t or u to choose the time and power percentage and press p or q to increase or decrease the time and power percentage value 4 After all value settings are set press OK to save...

Page 5: ...ing in power Check the power supply Reset power supply Check the adapter Change to another adapter Check the controller Change to another controller Fail to control ballasts Check the connection of controller and ballasts make sure each connection is good Reconnect the wires Controller doesn t have any temperature display after temperature probe connected Check if the temperature probe is damaged ...

Page 6: ...s trying to ignite the lamp Ignition busy Flash 6 7 Lamp voltage is too high or too low Lamp fault Flash 7 14 LED failure indicator on electronic ballast Note 1 Without controller connected Dimming LED indicator will remain on If failure occurs the Turbo LED indicator will flash one of seven possible issues listed above 2 With controller connected The controller LED will remain on and flash Contro...

Reviews: