9
F
Fiig
gu
urre
e 2
2--5
5 Bottom view
2.2.6 Emergency Stop Button
Press the emergency stop button to quickly stop the machine in an emergency. The po-
sition is shown in the figure below.
F
Fiig
gu
urre
e 2
2--6
6 Bottom view
Before maintenance, press the emergency stop button to prevent the machine
from being connected to the power supply due to background misoperation.
2.3
Circuit Diagram
The converter can convert the DC current from the battery into DC current that can be
accepted by power conversion equipment such as inverters and battery storage con-
verters. This is used to perform the power conversion. It is also be used to convert the
DC power output from the power conversion devices into DC power can be used to
charge the battery. The specific conversion direction is determined by the state of the
battery and can be controlled by the monitoring system.
Design principles of the converters are as follows:
User Manual