6
standby mode and the light turns off. The setting is not
saved.
There are 4 PIR sensitivity displays:
FIGURE 27
4. ID CODE LEARNING
When in PIR sensitivity settings, press
Set
to enter ID
code learning mode. The LCD displays as below:
FIGURE 28
Press
Set
and the light stays on to remind user the unit
is operating. Once the unit enters ID code learning
mode, press
Set
for 3 seconds. The light will flash and
the unit starts ID code learning. A thirty second
countdown will start and the LCD displays as per below
(FIGURE 29);
FIGURE 29
If ID code learning is not finished within 30 seconds, it
fails coding and the LCD returns back to standby mode.
If ID code learning is successful, the LCD returns back
to standby mode and PIR stops detecting function for
one minute.
Once the unit receives RF signals for scene changing,
the light flashes once and then turns on steadily for 10
seconds implying the scene change is in progress.
After 10 seconds the light turns off. The setting is
completed within one minute after the RF signal is
received.
The unit can learn up to 12 ID codes. If you ever wish
to clear ID codes, enter ID code learning mode. The
thirty second countdown starts and press
Set
for 6
seconds. Please note that when ID code clearing is
executed, ALL ID codes recorded in the unit will be
cleared.
To ensure learning or clearing is successful, you can
use the remote control to switch between scenes.
Please refer to the user manual for the remote control
for more operating information.
If unit receives TURN ON signal
It operates as a working light while the function of
camera and PIR detection is off
If unit receives TURN OFF signal
The PIR and LUX detection of the unit are still
active, but the light only turns on at night while
camera is off
Note:
Under ID code learning mode, if no action is
taken within 12 seconds the settings are not saved and
the LCD returns back to standby mode (the light turns
off).
SETTING THE LIGHTING SYSTEM
(1) TIME ADJUSTMENT
The TIME adjustment controls how long the light stays
on after motion has been detected, as well as video
recording time. Three lengths of time are available for
selection: 20 seconds, 1 minute and 5 minutes. Turn
the TIME control knob to the position of 20s, 1min or
5min (FIGURE 30). Please ensure the control knob
has been turned and set to the accurate position.
FIGURE 30
Note:
While setting the time, if the PIR keeps detecting
motion, the lighting time will be extended (video
extended as well). Once time is up (i.e. 20 seconds, 1
minute or 5 minutes), the recording will stop. It takes 2
seconds before the next recording can be active.
(2) LUX ADJUSTMENT
The LUX adjustment determines at what light level the
light starts operating.
To start turn the LUX control knob to the edge with the
moon (dusk) position (FIGURE 31). In this provisional
setting mode, the Motion Sensor remains inactive
during daylight. At dusk when you have found the LUX
level desired for operation, simply set the LUX control
knob to the position desired (which will allow the sensor
to become active as daylight declines)
Sensitivity 4
(Lowest Sensitivity)
Sensitivity 1
(Highest Sensitivity)
Sensitivity 2
Sensitivity 3