26 SUNFAR C300
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code
Name
Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F3.0
Function selection of input
terminal 1 (0~25)
1 1
★
F3.1
Function selection of input
terminal 2 (0~25)
1 2
★
F3.2
Function selection of input
terminal 3 (0~25)
1 3
★
A
u
xili
ar
y
ru
nn
ing p
a
ra
met
e
r un
it
F3.3
Function selection of input
terminal 4 (0~25)
0
:
Control terminal is idle
1
:
Multi-speed control terminal 1
2
:
Multi-speed control terminal 2
3
:
Multi-speed control terminal 3
4
:
Wobble freq. is valid
5
:
State of wobble freq. reset
6
:
FWD jog control
7
:
REV jog control
8
:
Acc& Dec time selection terminal 1
9
:
Acc& Dec time selection terminal 2
10
:
Freq. setting channel selection 1
11
:
Freq. setting channel selection 2
12
:
Freq. setting channel selection 3
13
:
Freq. is controlled gradually increase
(
UP
)
14
:
Freq. is controlled gradually increase
(
DW
)
15
:
UP-DW freq. clear
16
:
Uncontrolled stop control
17
:
Fault signal of peripheral equipment
input
18
:
Three-line mode running control
19
:
DC braking control
20
:
Inner counter clear
21
:
Inner counter timer
22
:
PLC running valid
23
:
PID running valid
24
:
Reserved
25
:
PLC state reset after stopping
1 6
★