SB--7--621
Page 8
RECOMMENDED LUBRICANT
Gear
Diameter
Vertical
Horizontal
2”
1/4 PT.
1/2 PT.
3”
1/3 PT.
2/3 PT.
4”
3/4 PT.
1 PT.
5”
1 PT.
2--1/4 PT.
FIGURE 4 -- APPROXIMATE OIL CAPACITIES
The factory recommended lubricant is AEON PD
Synthetic Lubricant.
AEON PD is formulated
especially for positive displacement blowers to provide
maximum protection at any temperature. One filling of
AEON PD will last a minimum of 4 times longer than a
premium mineral oil, depending on actual operating
conditions. AEON PD contains a special additive pack-
age designed for greater rust and corrosion protection.
AEON PD Lubricant
Description
Part Number
1 Quart
28G23
Case/12Quarts
28G24
5 Gallon Pail
28G25
55 Gallon Drum
28G28
AEON PD Food Grade Lubricant
Description
Part Number
1 Quart
28H97
Case/12Quarts
28H98
5 Gallon Pail
28H99
55 Gallon Drum
28H100
FIGURE 5 -- AEON PD SYNTHETIC LUBRICANT
Machines are shipped without oil in
the sump. Do not operate before
adding lubricant.
LUBRICATION INSTRUCTIONS
Filling Procedure (For 2” and 3” sizes)
Refer to FIGURE 3, page 7. Remove the oil level plug
(H) and the square head vented oil fill plug (B) from the
gear cover. Add oil to the gear case until oil drips out
of the oil level hole (H). Secure plugs in their correct
location.
Filling procedure (For 4” and 5” sizes)
Refer to FIGURE 3, page 7. Remove the breather (B)
from the gear cover. Add oil to the gear case until oil
reaches the center of the oil level gauge (H). Secure
breather (B) in the gear cover.
Add fresh oil as required to maintain proper level. The
oil level should be at the middle of the sight glass when
the machine is not operating.
Do not overfill as this will tend to
cause excessive heating of the gears
and may damage the unit.
AEON PD Synthetic Lubricant should be drained after
6000 hours of operation. Re--fill with fresh AEON PD
oil. If mineral oil is used, perform the above oil--change
maintenance every 1500 hours.
Recommended
service intervals are for normal blower operating condi-
tions. Severe operating conditions may warrant more
frequent oil changes. Laboratory analysis of lubricant
should be used to help determine the optimum oil
change interval.
For best performance and equipment protection, use
AEON PD Synthetic Lubricant, which has been specifi-
cally formulated for positive displacement blowers. If
you choose not to use AEON PD Synthetic Blower
Lubricant, select an oil with rust and oxidation inhibi-
tors, anti--foam additives, and the viscosities listed in
FIGURE 6, page 9. Do not use an oil that contains EP
additives.
Flush the oil whenever a change is
made from one type of oil to another.
Drain the current lubricant as thoroughly as possible.
Refill with the new lubricant. Fill to normal level of the
blower, which is at the middle of the sight glass when
the machine is not operating. Run the blower for one
hour. Shut off the blower and drain the lubricant com-
pletely. Refill the blower again with the new lubricant.
Summary of Contents for Gardner Denver Sutorbilt Legend GAA P Series
Page 33: ...SB 7 621 Page 25 SECTION 8 PARTS LIST 300GAA810 B Ref Drawing ...
Page 35: ...SB 7 621 Page 27 200GAB810 D Ref Drawing ...
Page 37: ...SB 7 621 Page 29 300GAC810 A Ref Drawing ...
Page 39: ...SB 7 621 Page 31 300GAC810 A Ref Drawing ...
Page 42: ...Sunco Powder Systems Inc Blower Division Phone 704 545 3922 www suncoblowers com ...