SB--7--621
Page 10
SECTION 4
OPERATION
Future operating problems can be avoided if proper
precautions are observed when the equipment is first
put into service.
Before starting under power, the blower should be
turned over by hand to make certain there is no binding,
or internal contact.
Each size blower has limits on pressure differential,
running speed, and discharge temperature which must
not be exceeded. These limits are shown in the follow-
ing tabulation.
Operating beyond the specified oper-
ating limitations will result in damage
to the unit.
It is important that the pressures and temperatures are
measured directly at the ports of the blower to avoid
error that may be caused by intervening pipe runs,
fittings, etc.
Relief valves should be used to protect against exces-
sive pressure or vacuum conditions. These valves
should be tested at initial startup to be sure they are
adjusted to relieve at or below the maximum pressure
differential rating of the blower.
Relief valves should be placed as
close as possible to the blower inlet
or discharge.
In some instances, pressure may be relieved at a lower
point than the blower maximum in order to protect the
motor or the equipment served by the blower.
Discharge temperature switches are recommended to
protect against excessive inlet restriction or inlet
temperatures. Check valves in the discharge line on
pressure blowers and in the inlet line on vacuum
blowers are recommended to protect the blower from
motoring backwards when shut down under load.
LIMITATIONS
For
information
regarding
limitations,
refer
to
FIGURE 7, below.
MAXIMUM OPERATING LIMITATIONS
PRESSURE
VACUUM
DISCHARGE
SIZE
RPM
PSI
IN HG
TEMPERATURE
_
F
2LP
5275
7
14
285
2MP
5275
12
15
315
3LP
3600
7
14
260
3MP
3600
12
15
280
3HP
3600
15
16
320
4LP
3600
7
14
260
4MP
3600
10
16
285
4HP
3600
15
16
310
5LP
2850
7
14
260
5MP
2850
13
16
280
5HP
2850
15
16
300
DO NOT EXCEED THESE LIMITS
FIGURE 7 -- MAXIMUM OPERATING LIMITATIONS
Blower speed, line losses, elevation, and increased inlet temperatures
will affect the maximum operating limitations.
Summary of Contents for Gardner Denver Sutorbilt Legend GAA P Series
Page 33: ...SB 7 621 Page 25 SECTION 8 PARTS LIST 300GAA810 B Ref Drawing ...
Page 35: ...SB 7 621 Page 27 200GAB810 D Ref Drawing ...
Page 37: ...SB 7 621 Page 29 300GAC810 A Ref Drawing ...
Page 39: ...SB 7 621 Page 31 300GAC810 A Ref Drawing ...
Page 42: ...Sunco Powder Systems Inc Blower Division Phone 704 545 3922 www suncoblowers com ...