Sunco Blowers www.suncoblowers.com Phone: 704-545-3922 Pg. 8
All rights reserved. No part of this manual may be reproduced in any form by any
means without permission from
Sunco Blowers
CW or CCW
Inlet CFM
2, 5
(@maximum speed and maximum Dp
)
176 311 527 862 1521
2242
Power Consumption
3, 5
(BHP @ maximum speed and maximum Dp)
Blower
7.1
(7 psi)
12.5
(7 psi)
20.4
(7 psi)
32.3
(7 psi)
58.7
(7 psi)
72.7
(7 psi)
Vacuum
7
(14 InHg)
12.2
(14 InHg)
20
(14 InHg)
31.6
(14 InHg)
57.8
(14 InHg)
12.2
(14 InHg)
Operating Limits
Max RPM
5275 3600 3600 2850 2350 2050
Max Case Pressure,
25 (psig)
Max Dp Blower
4,5
(psi)
7 7 7 7 7 7
Max Dp Vacuum
4,5
(InHg)
12 14 14 14 14 14
Max Pressure Ratio
4
1.88:1 1.88:1 1.88:1 1.88:1 1.88:1 1.88:1
Max Discharge Temp.
̧
238 248 239 239 248 198
Max Inlet Temp.
̧
104
Connection
Inlet Port (ANSI)
Discharge Port (ANSI)
NPT 2”
NPT 2.5”
NPT 3”
NPT 4”
6”
8”
Weight
(lb)
60 111 162 285 529 838
Notes:
1. The user can select the configuration according to their installation requirements.
2. The effective volume flow is dependent on the speed and the differential pressure.
3. The power consumption is dependent upon the operating point required, e.g. volume-flow
and differential pressure.
4. The ratings based on inlet air at standard pressure of 14.7 psia, standard temperature of 68
degrees F, and specific gravity of 1.0.
5. Dp = discharge pressure – inlet pressure
4.2. Ambient Temperatures
Minimum ambient temperature *………........................................................ 5 °F
Maximum ambient temperature *…………………………………. .............. 104 °F
* These temperature limits are based on lubricants specified here within. Consult Eurus
Blower for recommendations if operating environment temperatures exceed limits (see