background image

12

3. Slowly turn the calc clean boiler cap anti 

clock wise. See fig 7.

Note:

 The boiler cap needs to be released 

slowly to release any remaining water.

4.  Remove the calc clean valve 

completely. See fig 8. 

5.  Place the unit on its side and remove 

any remaining water. Carefully pour 
the descaling solution into the boiler. 
Replace the calc clean valve.

6.  Return the unit to the upright position 

and leave for 2 minutes.

7.  Shake the unit back and forth to 

dislodge any scale build up on the base 
of the boiler. Leave for 10 minutes.

8.  Shake the unit again to swirl the 

solution around inside the boiler.

9. Place the unit on a sink or vessel so 

that water can be expelled from the 
boiler.

10. Carefully remove the calc clean valve 

and ensure the descaling solution is 
emptied.

11. Rinse with 400ml of water (90 degrees 

is recommended), shake and empty. 
Repeat rinsing process at least 2 
times.

12. Once you have completed the descaling 

process, and refilled the tank, press 
and hold the Power button for 3 
seconds to switch off the Calc Clean 
indicator light. The power light will 
illuminate and the unit will begin 
heating as normal.

Note:

 Sunbeam Steam Ironing System 

descaling tablets (SR0100) are available 
from selected department stores and 
electrical retailers.

Calc Clean instructions – using lemon juice

Alternatively, if you do not have Sunbeam 
Ironing System Descaling Tablets, you can 
use lemon juice to remove the scale build 
up from inside the unit’s boiler.
1.  To flush the boiler, turn the unit off 

and wait for it to cool completely 
(approx 2 hours).

2.  Place the unit on a waterproof surface, 

or on the edge of the sink. 

3.  Slowly release the calc clean boiler cap 

to release any remaining water.

CAUTION:

 If the unit has been used prior to 

descaling the boiler the calc clean boiler 
cap will be very hot. Ensure that the unit 
has cooled completely before commencing 
the calc cleaning process.
4.  Empty any remaining water from the 

boiler.

5.  In a small jug, add 3 tbs lemon juice 

to 400ml of warm water (90 degrees is 
recommended) and stir to mix.

6.  Place the unit on its side and carefully 

pour the lemon solution into the boiler. 
Replace the calc clean boiler cap.

7.  Return the unit to the upright position 

and leave for 2 minutes.

Care and Cleaning continued

Figure 8

Summary of Contents for Pro Glide SR8710

Page 1: ...MASTER SERIES Pro Glide Steam Generator User Guide SR8710 SR8700...

Page 2: ...ant instructions retain for future use Contents Sunbeam s Safety Precautions 1 Features of your Pro Glide Steam Generator 2 Using your Pro Glide Steam Generator 5 Care and Cleaning of your Pro Glide S...

Page 3: ...ecommend the use of a residual current device RCD with a tripping current not exceeding 30mA in the electrical circuit supplying power to your appliances Do not immerse the appliance in water or any o...

Page 4: ...the iron on the heat resistant iron rest between garments Refillable water tank cover The removable 1400ml capacity tank has a large filling hold to make it easier to refill during ironing The tank i...

Page 5: ...the steam release trigger to produce a constant stream of high powered steam to reduce your ironing time and effort Steam will not be emitted from the iron when the steam release trigger is not depres...

Page 6: ...green when the level has been reached Low Water Indicator The low water indicator illuminates RED when it is time to refill the water tank Calc Clean Boiler Cap The calc clean indicator on the control...

Page 7: ...e from selected retailers Filling the steam generator tank with water The tank can be removed and refilled from the tap or using a jug through the water inlet Do not exceed the maximum water level ind...

Page 8: ...stable at the new setting by allowing the thermostat to cycle once the thermostat light will turn on off once 4 Select the desired steam level by turning the Steam Rate dial to the desired setting as...

Page 9: ...ut the boiler may take a few minutes to return to the correct temperature 1 Using a jug slowly pour water into the water inlet until the maximum water level is reached Do not exceed the maximum water...

Page 10: ...ir to release any remaining condensation Calc Clean Reminder Mineral deposits in tap water solidify when the water is heated and can build up in the steam holes and boiler system which can affect stea...

Page 11: ...surface Warning Do NOT empty the boiler during use or at anytime when the steam generator is hot Calc Clean Reminder Mineral deposits in tap water solidify when the water is heated and can build up i...

Page 12: ...indicator light The power light will illuminate and the unit will begin heating as normal Note Sunbeam Steam Ironing System descaling tablets SR0100 are available from selected department stores and...

Page 13: ...xpelled from the boiler 11 Carefully remove the calc clean valve and ensure the descaling solution is emptied 12 Rinse with 400ml of water 90 degrees is recommended clean water shake and empty Repeat...

Page 14: ...for the unit to cool down and then following the Care and Cleaning instructions on page 9 Once you have completed the descaling process and refilled the tank press and hold the Power button for 3 seco...

Page 15: ...lways use a pressing cloth to avoid shine marks Tip 6 Ironing the seam Always press seams in the same direction they were made When a garment is produced the fibres will naturally settle in the direct...

Page 16: ...under manufacturer s instructions Wool Medium Steam iron on wrong side or use an ironing cloth Wool Blends Medium Steam iron on wrong side or use an ironing cloth Cotton Blends Medium Check label and...

Page 17: ...Notes...

Page 18: ...Notes...

Page 19: ...problems or use of the product on incorrect voltage Should you experience any difficulties with your product during the warranty period please contact our customer service line for advice on 1300 881...

Page 20: ...786 232 mail Unit 3 Building D 26 Vestey Drive Mt Wellington Auckland New Zealand Sunbeam Corporation Limited ABN 45 000 006 771 Sunbeam Corporation is a division of GUD Holdings Limited Sunbeam is a...

Reviews: