WINTERIZATION

YOUR SOLAR SYSTEM MUST BE DRAINED FOR WINTERZATION! FREEZE DAMAGE IS NOT
COVERED UNDER THE MANUFACTURER’S LIMITED WARRANTY! YOU MUST DRAIN YOUR
SOLAR COLLECTORS JUST LIKE YOU DRAIN THE REST OF YOUR POOL EQUIPMENT!

Remove the vacuum relief valve at the top solar system. Remove the rubber end cap at the bottom and be sure ALL the water is
drained out of the system. Replace end caps and blow pressurized air in the reverse direction of normal water flow. This is the
most effective way to drain your system. You can leave the collectors in place (as long as they are completely drained) and they
will withstand even the harshest winters. Sun2Solar recommends that you store your collectors inside in a warm dry place.

COLLECTOR REPAIR

IF A COLLECTOR DEVELOPS A LEAK

Your solar collectors are warranted against defects in materials and workmanship (see warranty for details and limitations). If a
leak develops for any other reason, you may use the repair method shown. The collectors are not warranted against freeze
damage.

SOLAR COLLECTOR REPAIR

This method allows for an easy and permanent, on-site repair of a collector by isolating the leading riser tube. Referring to the
figure at the right, locate the tube to be isolated

.

Using a sharp utility knife, very carefully cut away approximately 1”

(2.54

cm)

of the tube at the both headers. Drive #10 sheet metal screw, preferably stainless, into the hole in the header. The screw

must be between ½” (1.27 cm) and ¾” (1.9 cm) long.

DO NOT OVER-TIGHTEN!

If the screw strips out, or if the repair

leaks, use a #12 screw. This repair method will not void the collector warranty. With proper care and winterization, you will
enjoy your solar collectors for many years.

AVAILABLE KITS OPTIONS

SM050004 INGROUND UNIVERSAL SYSTEM KIT

KIT COMPONENTS

QTY

1.5” Diverter Valve

1

3.75” Rubber Hose Connector

1

Pipe Adaptor

2

End Cap

1

Vacuum Relief Valve

1

Spring Check Valve

1

1.5” Stainless Steel Clamps

3

*Used for hard plumb installation

* Will support up to (8) 2 x 20 systems or (4) 4 x 20

803039 ABOVEGROUND MANUAL DIVERTER VALVE KIT

KIT COMPONENTS
1.5” Ball Valve

1

1.5”PVC Tees

2

Flex Hose Adaptors

4

*Used for flex hose installations* * Will support 2 x 20 and 4 x 20*

803030 MOUNTING KIT

KIT COMPONENTS

6’ Web Strapping

5

Stainless Steel Mounting Brackets

15

#14 Stainless Steel Screws

15

*Used for flex hose installations* * Will support 2 x 20 and 4 x 20*

SM050006 HIGH WIND ADD-ON MOUNTING KIT

Kit Components

QTY

6’ Web Strapping

4

Stainless Steel Mounting Brackets

4

#14 Stainless Steel Screws

4

**Use in conjunction with 803030 in areas of excessive wind **will support (1) 2’ x 20” collector**

Summary of Contents for 805401

Page 1: ...AL Model Sku s 805401 805430 805431 805404 805405 805406 805407 Read all instructions before assembling or using the Sun2Solar Heater Systems Retain this Manual for future use 03 16 Distributed By Mil...

Page 2: ...ing the Sun2Solar Heater on a roof fence or rack system When installing the collectors near the pool especially on an elevated rack system ensure that the structure does not provide access to the pool...

Page 3: ...14197 2 B 3 75 Rubber Hose Connector 108015 1 C PVC Elbow Connector 214083 2 D Rubber End Cap 108016 4 E Teflon Tape 274119 1 F Backwash Fitting 274062 2 INSTALLATION READ THE ENTIRE MANUAL PRIOR TO T...

Page 4: ...e the header with the white serial number label and install the PVC elbow connectors on either end of that header 8 Turn the pool pump off and ensure the handle of that filter is in the OFF CLOSED pos...

Page 5: ...label and install the rubber end caps on either end of that header 7 Locate the header with the white serial number label and install the PVC elbow connectors on either end of that header 8 Turn the...

Page 6: ...only For full collector installation please see the appropriate system layout provided in this manual 1 Once positioning is established locate the manufactured slots in the collector 5 slots in a 20...

Page 7: ...ht locate the tube to be isolated Using a sharp utility knife very carefully cut away approximately 1 2 54 cm of the tube at the both headers Drive 10 sheet metal screw preferably stainless into the h...

Page 8: ...the weather has it been cloudy or raining Use your pool cover at night to reduce heat loss Refer to our order guide pool size may require additional collectors Bubbles continue to appear from the pool...

Reviews: