SPARC T3-1 Server Installation Guide • March 2012
▼
Connect the NET MGT Port Cable
The service processor network management port is labeled NET MGT. This port is
located just to the right of the serial management (SER MGT) port on the rear panel.
●
Connect a Category 5 cable from the NET MGT network management port to
your network switch or hub.
FIGURE:
Service Processor Network Management Port – Rear Panel
Note –
This port is not operational until you configure the network settings (through
the serial management port).
Note –
The service processor network management port is configured by default to
retrieve network settings with Dynamic Host Configuration Protocol (DHCP) and
allow connections using Solaris Secure Shell (SSH). You might need to modify these
settings for your network. Instructions are given in
“Powering On the Server For the
First Time” on page 55
.
Related Information
■
“Connect the SER MGT Port Cable” on page 49
■