![Sun Oracle Netra SPARC T3-1B Service Manual Download Page 87](http://html.mh-extra.com/html/sun-oracle/netra-sparc-t3-1b/netra-sparc-t3-1b_service-manual_1393104087.webp)
Servicing Memory
75
5. Push the DIMM into the connector until the ejector tabs lock the DIMM in
place.
If the DIMM does not easily seat into the connector, verify that the orientation of
the DIMM is correct. Never apply excessive force.
6. Return the server module to operation.
See
“Returning the Server Module to Operation” on page 111
7. Perform one of the following tasks to verify the DIMM:
■
Verify a replacement DIMM. See
“Clear the Fault and Verify the Functionality
of the Replacement DIMM” on page 75
■
Verify additional memory. See
“Verify DIMM Functionality” on page 79
Related Information
■
■
“DIMM Configuration Reference” on page 81
▼
Clear the Fault and Verify the
Functionality of the Replacement
DIMM
This procedure describes how to clear a memory fault and how to verify the
functionality of the replacement DIMM.
Ensure that the following conditions are met:
■
The server module is in Standby mode (installed in a powered modular system,
but the server module’s host is not started).
See
“Prepare the Server Module for Removal” on page 58
■
You have connectivity to the SP.
See
“Access the SP (Oracle ILOM)” on page 15
1. Access the Oracle ILOM
->
prompt.
See
Summary of Contents for Netra SPARC T3-1B
Page 1: ...SPARC T3 1B Server Module Service Manual Part No E29280 02 July 2012 ...
Page 7: ...Contents vii Start the Server Module Host 114 Glossary 115 Index 121 ...
Page 8: ...viii SPARC T3 1B Server Module Service Manual July 2012 ...
Page 12: ...xii SPARC T3 1B Server Module Service Manual July 2012 ...
Page 116: ...104 SPARC T3 1B Server Module Service Manual July 2012 ...
Page 131: ...Glossary 119 W WWID World wide identifier A unique number that identifies a SAS target ...