Servicing Memory
73
▼
Remove a DIMM
Caution –
This procedure involves handling circuit boards that are extremely
sensitive to static electricity. Ensure that you follow ESD preventative practices to
avoid damaging the circuit boards.
Caution –
Components inside the chassis might be hot. Use caution when servicing
components inside the chassis.
1. (If needed) Prepare for service. See:
■
“Shut Down the Oracle Solaris OS” on page 56
■
“Prepare the Server Module for Removal” on page 58
■
“Remove the Server Module From the Modular System” on page 59
■
■
“ESD Safety Measures” on page 52
2. (If needed) Locate the faulty DIMM.
See
“Locate a Faulty DIMM (LEDs)” on page 70
.
3. Remove the DIMM from the motherboard as described in the following steps:
a. Push down on the ejector tabs on each side of the DIMM until the DIMM is
released (panel 1).
b. Grasp the top corners of the DIMM, and lift and remove it from the server
module (panel 2).
c. Place the DIMM on an antistatic mat.
4. Install a replacement DIMM.
See
Summary of Contents for Netra SPARC T3-1B
Page 1: ...SPARC T3 1B Server Module Service Manual Part No E29280 02 July 2012 ...
Page 7: ...Contents vii Start the Server Module Host 114 Glossary 115 Index 121 ...
Page 8: ...viii SPARC T3 1B Server Module Service Manual July 2012 ...
Page 12: ...xii SPARC T3 1B Server Module Service Manual July 2012 ...
Page 116: ...104 SPARC T3 1B Server Module Service Manual July 2012 ...
Page 131: ...Glossary 119 W WWID World wide identifier A unique number that identifies a SAS target ...
Page 132: ...120 SPARC T3 1B Server Module Service Manual July 2012 ...