![Sun Oracle Netra SPARC T3-1B Service Manual Download Page 86](http://html.mh-extra.com/html/sun-oracle/netra-sparc-t3-1b/netra-sparc-t3-1b_service-manual_1393104086.webp)
74
SPARC T3-1B Server Module Service Manual • July 2012
Related Information
■
“Install a Replacement DIMM” on page 74
■
“DIMM Configuration Reference” on page 81
▼
Install a Replacement DIMM
Caution –
This procedure involves handling circuit boards that are extremely
sensitive to static electricity. Ensure that you follow ESD preventative practices to
avoid damaging the circuit boards.
Caution –
Components inside the chassis might be hot. Use caution when servicing
components inside the chassis.
1. (If needed) Prepare the server module for service and remove the faulty DIMM.
See
.
2. Unpackage the replacement DIMM and set it on an antistatic mat.
3. Ensure that the DIMM ejector tabs are in the open position (panel 1).
4. Line up the replacement DIMM with the connector.
Align the DIMM notch with the key in the connector, as in panel 3. This action
ensures that the DIMM is oriented correctly. Panel 2 shows an incorrect alignment.
Summary of Contents for Netra SPARC T3-1B
Page 1: ...SPARC T3 1B Server Module Service Manual Part No E29280 02 July 2012 ...
Page 7: ...Contents vii Start the Server Module Host 114 Glossary 115 Index 121 ...
Page 8: ...viii SPARC T3 1B Server Module Service Manual July 2012 ...
Page 12: ...xii SPARC T3 1B Server Module Service Manual July 2012 ...
Page 116: ...104 SPARC T3 1B Server Module Service Manual July 2012 ...
Page 131: ...Glossary 119 W WWID World wide identifier A unique number that identifies a SAS target ...
Page 132: ...120 SPARC T3 1B Server Module Service Manual July 2012 ...