2-10
Sun Netra CP3220 Blade Server User’s Guide • January 2010
▼
To Install an ARTM
1. Verify that you have taken the necessary antistatic precautions.
See
Section 2.1.1, “Equipment and Operator Safety” on page 2-2
.
2. From the rear of the system, choose an appropriate slot for the ARTM.
The ARTM must be installed, inline, behind a compatible Sun Netra blade server
(Sun Netra CP3220 blade server or Sun Netra CP3260 blade server).
For example, if the Sun Netra CP3220 blade server will be installed in slot 3, the
corresponding ARTM must be installed at the back of the system in slot 3
(
FIGURE 2-1
). If you do not install the ARTM and the Sun Netra CP3220 blade
server in corresponding slots, the system will recognize the Sun Netra CP3220
blade server, but not the ARTM.
Note –
Slots 1 through 6 and 9 through 14 are available for Sun Netra CP3220 blade
servers. Slots 7 and 8 are reserved for the switch card.
3. Remove the slot filler panel from the selected slot, if necessary.
4. Retrieve the ARTM from the ship kit.
5. Prepare the ARTM by opening the injector/ejector latch at the top of the
module (
FIGURE 2-2
).
Summary of Contents for Sun Netra CP3220
Page 8: ...viii Sun Netra CP3220 Blade Server User s Guide January 2010...
Page 12: ...xii Sun Netra CP3220 Blade Server User s Guide January 2010...
Page 14: ...xiv Sun Netra CP3220 Blade Server User s Guide January 2010...
Page 34: ...1 16 Sun Netra CP3220 Blade Server User s Guide January 2010...
Page 78: ...3 8 Sun Netra CP3220 Blade Server User s Guide January 2010...
Page 94: ...4 16 Sun Netra CP3220 Blade Server User s Guide January 2010...
Page 117: ...Appendix B BIOS Screens B 3 FIGURE B 2 BIOS Main Menu FIGURE B 3 Advanced Configuration Menu...
Page 131: ...Appendix B BIOS Screens B 17...
Page 135: ...Index 4 Sun Netra CP3220 Blade Server User s Guide January 2010...