19.0 dRIVE LOAd
This error message indicates the autoloader failed to load a tape into a drive. Troubleshooting should begin
with retrying the drive load operation. For instructions on loading a tape to a drive via the front panel, refer
to Sun StorEdge L7 User’s Guide -> Operation and Maintenance -> Autoloader Modes -> Mode 1A – LOAD
DRV.
DP1:
Check to see if the error message is still present after retrying the drive load operation.
R1:
Error message is still present.
A1:
Cycle power to the autoloader.
A1:
Retry the drive load operation.
DP2:
Check to see if the error message is still present after retrying the drive load operation.
R2:
Error message still present.
A2:
Replace the autoloader.
R2:
Error message no longer present.
R2:
Continue normal autoloader operation.
R1:
Error message no longer present.
A1:
Continue normal autoloader operation.
20.0 dRIVE UNLd
This error message indicates the autoloader failed to eject a tape from a drive due to the drive not being
logically unloaded. Troubleshooting should begin with retrying the drive eject operation. For instructions on
ejecting a tape from a drive via the front panel, refer to Sun StorEdge L7 User’s Guide -> Operation and
Maintenance -> Autoloader Modes -> Mode 1B – EJECT DRV.
DP1:
Check to see if the error message is still present after retrying the drive eject operation.
R1:
Error message is still present.
A1:
Cycle power to the autoloader.
A1:
Retry the drive eject operation.
DP2:
Check to see if the error message is still present after retrying the drive eject operation.
R2:
Error message still present.
A2:
Replace the autoloader.
R2:
Error message no longer present.
R2:
Continue normal autoloader operation.
R1:
Error message no longer present.
A1:
Continue normal autoloader operation.
21.0 dRIVE HNdL
This error message indicates the autoloader failed to eject a tape from or load a tape to a drive due to a
drive ‘operate handle’ timeout. Troubleshooting should begin with retrying the drive eject or drive load
operation. For instructions on ejecting a tape from a drive via the front panel, refer to Sun StorEdge L7
User’s Guide -> Operation and Maintenance -> Autoloader Modes -> Mode 1B – EJECT DRV. For
instructions on loading a tape to a drive via the front panel, refer to Sun StorEdge L7 User’s Guide ->
Operation and Maintenance -> Autoloader Modes -> Mode 1A – LOAD DRV.
DP1:
Check to see if the error message is still present after retrying the drive eject or drive load operation.
R1:
Error message is still present.
A1:
Cycle power to the autoloader.
A1:
Retry the drive eject or drive load operation.
DP2:
Check to see if the error message is still present after retrying the drive eject or drive load
operation.
R2:
Error message still present.
A2:
Replace the autoloader.
R2:
Error message no longer present.
R2:
Continue normal autoloader operation.
R1:
Error message no longer present.
A1:
Continue normal autoloader operation.