Messages
82
T9840 User’s Reference Manual • September 2008
Revision YA • 95739
DumpAgain?
alternating with
CHK xxxx
, where
xxxx
is an FSC.
The tape drive detected the same error
within a minute.
Note:
The Service indicator is flashing.
IPL the tape drive. If the problem persists,
contact authorized service personnel.
DumpToHost
The dump or event log is being
transferred to the host; operator panel
switches are locked.
None
Exp ClCart
The cleaning cartridge is used up.
Replace the cleaning cartridge.
Fix CfgErr
The checksum does not match after an
IPL.
Contact authorized service personnel.
Init
xxxx
.
where
xxxx
is an
FSC
An initialization error occurred.
Contact authorized service personnel.
IPL Pend
The IPL switch has been pressed.
None
LOAD CC
The common controller code is loading;
IPL is proceeding.
None
LOAD ESCON
ESCON firmware is loading; IPL is
proceeding.
None
LOAD FIBRE
Fibre Channel firmware is loading; IPL is
proceeding.
None
LOAD FICON
FICON firmware is loading; IPL is
proceeding.
None
LOAD SERVO
The servo code is loading; IPL is
proceeding.
None
LOAD SCSI
SCSI firmware is loading; IPL is
proceeding.
None
LOAD
xxxx
,
where
xxxx
is an
FSC
The load or unload operation failed.
If the load failed, insert another cartridge tape. If
it loads successfully, suspect the original tape. If
another tape fails to load, IPL the tape drive.
If the problem persists, contact your Sun service
representative.
Loading
A cartridge tape is loading.
None
Locating
The tape drive is doing a high-speed
seek.
None
Memory Err
The IPL failed.
IPL the tape drive again. If the problem persists,
contact authorized service personnel.
NTReady A
A write-enabled VolSafe data cartridge is
in the process of a manual unload.
None
NTReady F
A write-protected tape is in the process of
a manual unload.
None
NTReady U
A write-enabled tape is in the process of
a manual unload.
None
Offline,
alternating
with *
The tape drive is offline.
Perform offline menu operations or exit the
menu system.
TABLE 5-2
Operator Panel Display Messages (Continued)
Display
Meaning
Recommended Action
Summary of Contents for StorageTek T9840
Page 1: ...StorageTekTM T9840 Tape Drive User s Reference Manual Part Number 95739 Revision YA ...
Page 2: ......
Page 6: ...4 T9840 User s Reference Manual September 2008 Revision YA 95739 ...
Page 12: ...10 T9840 User s Reference Manual September 2008 Revision YA 95739 ...
Page 14: ...12 T9840 User s Reference Manual September 2008 Revision YA 95739 ...
Page 20: ...18 T9840 User s Reference Manual September 2008 Revision YA 95739 ...
Page 40: ...Mixed Media Management 38 T9840 User s Reference Manual September 2008 Revision YA 95739 ...
Page 86: ...Messages 86 T9840 User s Reference Manual September 2008 Revision YA 95739 ...
Page 94: ...Performance Specifications 94 T9840 User s Reference Manual September 2008 Revision YA 95739 ...
Page 109: ......