Messages
92
T10000 Operator’s Guide • July 2008
Revision EA • 96174
CodCrFail2
The tape drive cannot read code from the
data cartridge tape.
Retry the operation, or try another cartridge
tape. If the problem persists, contact
authorized service personnel.
CodeUpDate
The firmware in the tape drive is being
updated from the host; the operator panel
switches are locked.
None
CodUpFail1
The tape drive cannot read the data
cartridge tape, or the tape drive cannot
position the data cartridge tape.
Try another cartridge tape.
CodUpFail2
The EEPROM failed.
Contact authorized service personnel.
CodUpFail3
The tape drive cannot read code from the
data cartridge tape.
Retry the operation, or try another cartridge
tape. If the problem persists, contact
authorized service personnel.
CodUpFail4
The data cartridge tape is not a code update
cartridge tape.
Try another code update cartridge tape.
If the problem persists, contact authorized
service personnel.
DatCrFail1
The tape drive cannot create (reformat or
reclaim) a cartridge tape.
Ensure that the data cartridge tape is write-
enabled, or try to reformat the tape on
another drive. If the problem persists, contact
authorized service personnel.
DmpCrFail1
The tape drive cannot create (reformat or
reclaim) a diagnostic dump tape.
Ensure that the data cartridge tape is write-
enabled. If the problem persists, contact
authorized service personnel.
DmpCrFail2
The tape drive cannot read the format of the
data cartridge tape.
Retry the operation, or try another cartridge
tape. If the problem persists, contact
authorized service personnel.
DmpWrFail1
The tape drive cannot write diagnostic data
onto the data cartridge tape, or the tape
drive cannot position the data cartridge
tape.
Contact authorized service personnel.
DmpWrFail2
There is no diagnostic dump data to process.
Contact authorized service personnel.
xxxx
:Dmp y
Alternates with * (an asterisk) after
completion of IPL, where
xxxx
=the FSC of
last dump data collected and
Y
=number of
uncollected dumps in non-volatile memory.
Contact authorized service personnel who
accesses the diagnostic data and collects it to
tape or to the host.
DumpAgain?
alternating with
Chk xxxx
, where
xxxx
is an FSC.
The Service
indicator is
flashing.
The tape drive detected the same error
within a minute.
IPL the tape drive. If the problem persists,
contact authorized service personnel.
DumpToHost
The dump or event log is being transferred
to the host; operator panel switches are
locked.
None
Exp ClCart
The cleaning cartridge is used up.
Replace the cleaning cartridge.
Fix CfgErr
The checksum does not match after an IPL.
Contact authorized service personnel.
TABLE D-1
Operator panel Display Messages (Continued)
Display
Meaning
Recommended Action
Summary of Contents for StorageTek T10000
Page 1: ...StorageTek T10000 Tape Drive Operator s Guide Part Number 96174 Revision EA ...
Page 2: ......
Page 6: ...4 T10000 Operator s Guide July 2008 Revision EA 96174 ...
Page 11: ...96174 Revision EA Contents 9 Index 111 ...
Page 12: ...10 T10000 Operator s Guide July 2008 Revision EA 96174 ...
Page 40: ...Rear Panel 38 T10000 Operator s Guide July 2008 Revision EA 96174 ...
Page 80: ...Drive Operations Menu 78 T10000 Operator s Guide July 2008 Revision EA 96174 ...
Page 82: ...80 T10000 Operator s Guide July 2008 Revision EA 96174 ...
Page 98: ...Translated Messages 96 T10000 Operator s Guide July 2008 Revision EA 96174 ...
Page 104: ...Environmental Requirements 102 T10000 Operator s Guide July 2008 Revision EA 96174 ...
Page 118: ...116 T10000 Operator s Guide July 2008 Revision EA 96174 ...
Page 119: ......