18
Sun Dual 10GbE SFP+ PCIe ExpressModule User’s Guide • August 2008
7. Slide the ExpressModule into the vacant ExpressModule chassis slot until the
ejector lever engages and starts to close (2 in the preceding figure).
Failure to align the ExpressModule correctly can result in damage with the
ExpressModule’s internal connection to the chassis midplane.
8. Complete the installation by closing the ejector lever until the latch snaps into
place (3 in the preceding figure).
Caution –
Do not use excessive force when installing the ExpressModule into the
slot. You might damage the ExpressModule’s connector. If the ExpressModule does
not seat properly when you apply even pressure, remove and carefully reinstall the
ExpressModule.
9. Detach the wrist strap.
10. Connect the Ethernet cables.