Sun Gold Power Co.,Ltd
www.
sungoldpower.com
12
:
Ground L
:
Live N
:
Neutral
③
Correctly connect AC output wire in accordance with cable sequence and terminal position shown in the
figure below. Please connect the ground wire at first, and then live wire and null wire. The ground wire is
connected to the ground screw hold through Oshaped terminal.
:
Ground L
:
Live N
:
Neutral
Note:
use thick ground cable as far as possible (with cable section not less than 4mm
2
), place the ground point
to be close to the solar charge inverter as far as possible and choose shorter ground wire to the greatest extent
Wiring method of PV input:
Before wiring, disconnect external breaker at first, and confirm whether the used cable is thick enough.
Please refer to chapter
“
2.2 Wiring Specification and Breaker Type
”
;
②
Correctly connect PV input wire in accordance with cable sequence and terminal position shown in the
figure below.