background image

Problem

Troubleshooting

Solution

Sunbed not tanning

1. Clean sunbed, see 

Thorough Periodic Cleaning

.

2. Ensure supply voltage is between 208 and 230V AC.
3. Replace lamps if lamp hours are greater than 800hrs.
4. Replace acrylic.

Lamps fail to light and timer display is blank

1. Make sure the unit is connected to a power source.
2. Check source of AC power.  Reset circuit breaker or replace

fuse.

Timer display changes to indicate a tanning time after the timer but-
ton is pressed but lamps do not come on

1. Bypass plug is not installed, see 

Electrical Connections

.

2. A non-Perfect Sun™ bypass has been used.
3. If remote is being used, other than T-Max® Manager, the

external timer may not be activated.

4. Remote wiring is incorrect, see the instructions provided

with the remote interface kit.

Timer display continues to show a 0 after the timer button is pressed

1. T-Max® Manager remote system has not yet been set. 
2. Sunbed address is not set correctly, see 

Remote

Connections

.

One or more lamps fail to light

1. Check that lamp is installed correctly.
2. Switch unlit lamp with a lamp that lights, if new lamp lights

and old lamp still does not, replace old lamp.

The canopy will not stay up

NOTE:

Gas springs are manufactured to hold the canopy in its

fully open position as well as allow it to rest fully closed. If
left open for an extended period of time some creep down
may occur. This is considered normal. Keep the unit closed
when not in use. If the canopy will not stay fully open when
raised...

1. Raise and lower the canopy a few times to lubricate gas

spring internal seals.

2. Replace gas springs.

Problem

Troubleshooting

Solution

My bed won’t work with the T-Max® Manager remote system

1. The sunbed must first be set to a unique address, see

Remote Connections

.

2. The bypass plug may be installed in the series in an inap-

propriate location.  Remove bypass plugs when using T-
Max® products.

When auto-addressing the first bed does not register an address

When using the auto address feature of the T-Max®
Manager you must wait 10 seconds from the time you start
the auto address function before addressing the first bed.

I forgot what address I set my sunbed to

By pressing the stop button and then the timer button, and
holding both for 3 seconds, the timer display will show the
sunbed’s address number. Press the stop button to exit
address mode.

My bed is connected to the T-Max® Manager remote system and
when the delay time has expired the timer display starts counting
down but the bed lights do not come on

The auto start feature of the remote system is disabled, see
the instructions provided with your remote system.

My bed, connected to a T-Max® Manager, did not display “dL” but
does indicate:

“0”

1. Remote device has not been set.
2. The sunbed has not been connected to the remote system,

see 

Remote Connections

.

a tanning time and the lamps have come on

1. Delay time of T-Max® Manager has not been set.
2. Delay time has expired and session has begun.

a tanning time but the lamps have not come on

Auto start function of T-Max® Manager has been turned off.
Press the timer button to turn on lamps.

26713-01A -  Page 7

Summary of Contents for 24 X-Power

Page 1: ...hildren the elderly or fair skinned people who always burn easily and either never tan or tan minimally should not use this equipment To use lie down on bench and pull canopy down as far as adjustment...

Page 2: ...isible damage Report the extent of any damage to the transportation company In addition to the hex wrench supplied in the hardware kit you will need a 2 Phillips screwdriver Allen head Bolt 5 16 x 1 Q...

Page 3: ...led Your sunbed will not operate without either the bypass plug or a remote system connected If remote operation is desired see Remote Connections 13 Place the bushings into hinge brackets 6 26713 01A...

Page 4: ...ided with your remote system to determine if it operates in this way To connect your sunbed to this type of system a remote interface kit is required Contact your place of purchase to obtain the kit F...

Page 5: ...ps will turn on and the timer will begin to count down If a tan ning time less than the displayed time is desired repeatedly press the timer button B to decrease the remaining time 2 Lift the canopy l...

Page 6: ...two pairs of numbers which indicate the num ber of hours of service then return to 0 example Display shows 08 then 54 This equals 854 hours NOTE If the unit is connected to a T Max remote device it ma...

Page 7: ...ll not stay fully open when raised 1 Raise and lower the canopy a few times to lubricate gas spring internal seals 2 Replace gas springs Problem Troubleshooting Solution My bed won t work with the T M...

Page 8: ...es do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you No one has authority to change or modify this Limited Lifetime Warranty in any respect T...