INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
28
SUMMIT PUMP MODEL 2175
APPENDIX G – ANSI B15.1 COUPLING GUARDS
11.4 INSTALLATION INSTRUCTIONS FOR SUMMIT PUMP
ANSI B15.1 COUPLING GUARDS
Before assembling or disassembling the
coupling guard, lockout and tag out the
motor or controller/starter.
Before starting pump, replace the coupling
guard. Summit Pump assumes no liability
when these procedures are avoided
Figure G-1
The design’s simplicity allows complete coupling guard assembly, including the end
plate (pump end), in about fifteen minutes.
11.4.1 ASSEMBLY PROCEDURES
TO ASSEMBLE YOUR COUPLING GUARD
If the end plate (pump end) was previously
installed, make any necessary adjustments
to the coupling and skip to
Step 2
1. On the STO, MTO, and LTO, align the end plate (pump end) to the bearing frame.
(Impeller adjustment is not required.)
On the XLO-X, align the end plate (pump end) to the pump bearing housing with the
small slots on the end plate aligned to the impeller adjusting bolts and the large slots
clearing the bearing housing tap bolts. Then attach the end plate to the bearing housing