5.1.2 Grease Lubrication
Regrease grease lubricated bearings with NLG1 No. 2 consistency grease for pumpage
temperatures -60
°
F to 350
°
F. Grease is not recommended for temperatures above
350
°
F. Regrease bearings every three months.
Table 4
Acceptable Lubricating Oils
Chevron GTS Oil
46
68
100
Exxon Terrestic
46
68
100
Lubriplate
AC1
AC2
AC3
Mobil: DTE
Medium Heavy
Mobil: Synthetic
525
626
627
Shell: Tellus Fluids HD
46
68
100
Table 5
Acceptable
Greases
Citgo
Mystic EP2
Keystone
81EP2
Mobil
Mobil Grease XHP222
Mobil Synthetic
SCH 100
TO REGREASE LUBRICATED BEARINGS
1. Wipe dirt and foreign matter from the fittings.
2. Remove grease relief plugs from the bottom of the frame.
3. Fill grease through fittings until it comes out through the relief holes.
4. Reinstall grease relief plugs.
5.2 ROTATION
TO ROTATE THE PUMP
1. Lock out power to the pump driver.
2. Remove the coupling guard and coupling.
3. Momentarily restore power and energize the motor to determine rotation.
4. Confirm that motor rotation coincides with proper pump rotation. The proper pump
rotation is counterclockwise when facing the pump’s suction.