Using the burners
List of advised pot diameters to be used
on related burners:
Normal burner: 18-20 cm (7 - 8")
Rapid burner: 22-24 cm (8½ - 9½")
Auxiliary burner: 12-18 cm (4¾ - 7")
Normal burner: 18-20 cm (7 - 8")
The large flame symbol indicates the
highest cooking power. In turned-off
position (top), gas is not supplied to the
burners.
Igniting the gas burners
1. Keeping the burner knob depressed,
turn it counter-clockwise to the large
flame symbol.
2. An ignition spark is generated and the
gas is ignited.
3. Adjust the flame to the desired
cooking power.
4. If there is no electricity, ignite the gas
with the gas lighter.
Turning off a gas burner
Turn the knob to Off (top) position.
Gas shut-off safety system
As a counter-measure
against blow-out due to
fluid overflows at burners,
a safety mechanism trips
and shuts off the gas. To
re-ignite the burner:
•
Push the knob inward
and turn it counter-clockwise to ignite.
•
After the gas ignites, keep the knob
depressed for 3-5 seconds more to
engage the safety system.
•
If the gas does not ignite after you
press and release the knob, repeat
the procedure but keep the knob
depressed for 15 seconds.
CAUTION!
Risk of explosion in the
presence of unburned gas!
•
Do not press the knob for longer than
15 seconds if there was no ignition.
•
Wait for one minute and then repeat
the ignition process.
1 Gas shut-off
safety device
24