background image

21

 

 

TROUBLESHOOTING 

If any irregularities occur during normal operations, turn the dryer off, and wait one minute. Turn 
the dryer back on, and repeat the drying program. Most errors can be solved by trying the 
suggestions below:  
 

Problem/error 

Cause 

What to do? 

The machine will 
not start. 

• 

The dryer is not turned 
on. 

• 

Check whether the main power switch 
is on. 

• 

There is no voltage in the 
power outlet. 

• 

Check the fuse. 

• 

Check if the power cord plug is 
correctly inserted into the power outlet. 

There is voltage in 
the outlet, but the 
drum does not 
spin and the 
appliance does not 
work. 

• 

The door is not shut. 

• 

Check if the door is closed properly. 

• 

The condensation tank is full. 

• 

Empty the condensate tank. 
See the CLEANING AND 
MAINTENANCE section. 

• 

The 

START DELAY 

function was set. 

• 

Program was not started in 
accordance with the 
instructions. 

• 

To deactivate the start delay option, 
press the (8) 

START DELAY 

button

 

and hold for 3 seconds. 

• 

Re-read the instructions for use again. 

The appliance 
stops heating 
completely during 
a program. 

• 

The net filter may be 
clogged. As a result, the 
temperature in the dryer 
rises, which causes 
overheating, and therefore 
heating is switched off. 

• 

Clean the net filter. See the CLEANING 
AND MAINTENANCE section. 

• 

Wait for the appliance to cool down, 
and try running it again. If the dryer 
still fails to start, call a service 
technician. 

A slight hitting 
noise appears. 

• 

If the dryer is out of use for 
a long period of time, the 
support elements are under 
stress at the same point. 

• 

The noise will subside without any 
intervention. 

The door opens 
during drying. 

• 

There is too much laundry 
in the drum.  

• 

Remove some amount of laundry. 

Unevenly dried 
laundry. 

• 

Laundry of varying types 
and thickness was dried at 
the same time, or there was 
an excessive amount of 
laundry dried in one load. 

• 

Make sure you have sorted the 
laundry by type and thickness, 
whether you have added a suitable 
amount of laundry to the drum, and 
whether you have selected a suitable 
program. See the PROGRAM TABLE 
section. 

Laundry not 
dried or drying 
takes too long 

• 

Filters are not clean. 

• 

Clean the filters. See the CLEANING 
AND MAINTENANCE section. 

 

• 

The dryer is placed in a 
closed room,  the room is 
too small, or the room is too 
cold. The ambient air 
overheats as a result. 

• 

Make sure there is adequate supply of 
fresh air to the dryer. For example, 
open the door and/or window. 

• 

Check if the temperature in the room 
where the dryer is installed is too 
high or too low. 

Summary of Contents for LDHP24

Page 1: ...LL SAFETY RULED AND OPERATING INSTRUCTIONS Write Model and Serial Numbers here Model _____________________ Serial No __________________ Summit Appliance Division of Felix Storch Inc An ISO 9001 2015 r...

Page 2: ...abels 10 Dryer Cycle Table 11 Using a Dryer Basket 12 Selecting Extra Functions 13 14 Extra Function Table 15 End of the Drying Cycle 15 Drying Cycle Interruptions 15 16 Changing the Drying Cycle Func...

Page 3: ...nician or an authorized person Before connecting the dryer to the power mains wait for at least 2 hours until it reaches room temperature In case of a defect only use approved spare parts by authorize...

Page 4: ...dry laundry that was washed with water Do not dry any laundry that was washed or cleaned with flammable cleaners or substances such as gasoline trichloroethylene etc as this may result in an explosion...

Page 5: ...t 9 Heat Pump Filter 10 Rating Plate 11 Power Cord 12 Condensate Discharge Hose 13 Adjustable Feet TECHNICAL INFORMATION Power Supply 208 240V 60Hz Rated Current 15 A Drying Capacity 17 6 lbs Refriger...

Page 6: ...verheating The vents on the back wall and the air exhaust opening on the front side of the dryer should never be obstructed Use the clearances outlined below for optimum dryer operation Install the dr...

Page 7: ...support a and vacuum feet b if they are not supplied is available for purchase at the service units The surface on which the appliance is placed must be clean and level The washing machine onto which...

Page 8: ...low the top cover 2 Attach the hose into a drain no more than 31 80cm from the floor Connecting the Appliance to the Power Supply Before connecting the dryer to the power supply wait for a least two h...

Page 9: ...l be illuminated next to the drying cycle you have selected 2a See the dryer cycle table below if you are unsure which drying cycle is correct The START PAUSE button 3 will flash when the drying cycle...

Page 10: ...rusting Laundry Warning Labels Normal wash Sensitive laundry Max washing temperature EXTRA HOT Max washing temperature HOT Max washing temperature WARM Hand wash only COLD Do not wash Bleaching Bleac...

Page 11: ...his program to dry highly delicate laundry made of synthetic fibers which may be slightly moist after the drying process We recommend using a special purpose laundry bag Shirts 4 4 lb 2 kg Use this pr...

Page 12: ...to the door gasket as shown to the left 3 The basket can be used for the drying of sports shoes slippers or any other item you do not wish to be tumbled around the dryer drum during the drying proces...

Page 13: ...d on the power consumption of your selected drying cycle and any extra functions or settings The more the symbol is lit the more economical the drying cycle and the lower the power consumption The les...

Page 14: ...pened the Anti Crease setting will be deactivated Child Lock To activate and deactivate the Child Lock press and hold the 9 and 12 buttons at the same time for at least three seconds until the key sym...

Page 15: ...vated will flash Drying Cycle Interruptions Press the START PAUSE button to pause resume a drying cycle To stop and cancel the drying cycle press the START PAUSE button and hold it for 3 seconds The s...

Page 16: ...e laundry and press the button START PAUSE button to resume the drying cycle NOTE The drying time may be extended if addtional items are added to the unti after the drying cycle has started Personal S...

Page 17: ...light on the START PAUSE button will flash Rotate the program selector knob or press the ON OFF button or open the dryer door to reactivate the display If you do not do anything for 5 minutes after t...

Page 18: ...d during the cleaning process It is recommended that you place an absorbent cloth on the floor 1 Open the outer cover Hold the levers on the inside cover and rotate them upwards Remove the inside cove...

Page 19: ...tective gloves when cleaning the heat exchanger The dust and dirt in the metal fins of the heat exchanger can be cleaned with a vacuum cleaner and a soft brush attachment Access to the heat exchanger...

Page 20: ...s as shown to the left 2 Empty the condensation tank 3 Pull out the spout at the opening for easier emptying Replace the condensation tank Cleaning the Dryer CAUTION Always disconnect the dryer from t...

Page 21: ...ing and therefore heating is switched off Clean the net filter See the CLEANING AND MAINTENANCE section Wait for the appliance to cool down and try running it again If the dryer still fails to start c...

Page 22: ...ying program Drum lighting error There is no lighting when the dryer door is opened Disconnect the dryer from the power mains and call an authorized service unit If your appliance shows other symptoms...

Page 23: ...on the display unit and description of warning What to do Condensate tank warning Empty the condensate tank before resuming the program see the CLEANING AND MAINTENANCE Emptying the condensate tank s...

Page 24: ...ng Partial 1000 0 59 65 NOTE The parameters in this table are for your reference only The actual parameters may be different than the ones listed above Cotton Drying The Cotton Normal program is inten...

Page 25: ...mounts with programs for drier laundry or with the timed program DISPOSAL Packaging is made of environmentally friendly materials that can be recycled disposed of or destroyed without any hazard to th...

Page 26: ...26 NOTES...

Page 27: ...27 NOTES...

Page 28: ...lumbing codes or use of products not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthori...

Reviews: