Thermostats:
Select a location which is r
epresentative of the average
house temperature, usually the living room. The thermo-
stats should be mounted on an inside wall, never where
they will be subjected to drafts (warm or cold), above a
radio or television set, or where the sun’s rays or heat
from registers will affect them. See instructions supplied
with the thermostats.
For masonary chimneys refer to C.S.A. B1398 (p. 83). For
All Fuel chimneys consult manufacturers’ tables.
Fur
nace Assembly: Drawing #4
Locate Heat Exchanger Section in desir
ed area
Four location points for locating blower port are supplied
on left and right side of furnace section, burner end.
Cut desired side for blower to enter furnace section.
Place blower section against furnace section and attach
with screws.
Furnace must be assembled as per drawing and fan-limit
control location identical to drawing, casing screw holes
are provided for exact locations. See Drawing No. 1.
Wire according to wiring diagram.
How T
o Mount The Burner:
The bur
ner is flush mounted with three positioning bolts
on the front plate. Connect the burner conduit cable pro-
vided on the wiring harness - follow wiring diagram.
Check nozzle size, tightness and chamber alignment.
Set up burner to #1 Smoke.
Wiring The Fur
nace: Drawing #3
Each fur
nace is supplied with the necessary wiring har-
ness. Follow diagrams for wiring and correct location of
the controls included in these instructions.
All electrical equipment and wiring has to installed follow-
ing the requirements of the Canadian or U.S. electrical
code as well as regulations of local authorities.
Solid Fuel Damper Contr
ol: Drawing #1
The thermostat for the solid fuel section activates the
damper control - which in turn moves the damper flap. It
is essential that the damper control is at all time in per-
fect working order.
Note: Adjust damper chain so that damper flap opens no
more than 1/2”.
When oil is used as fuel close all combustion air inlets to
solid fuel side of furnace. Excessive air decreases the oil
burner efficiency.
How T
o Install Fire Brick: Drawing #2
1. Install 6 brick in floor of fir
ebox (see layout)
2. Place bottom row of bricks (for fire box sides, front
and back), making sure bricks are in brick plate
support frame which is an integral part of the box.
3. Repeat second and third rows of brick.
4. Install stainless steel front brick guard using bolts
provided.
5. Install “U” shaped top brick guard, inserting open ends
of guard into loops provided on inside of door opening.
Note: Due to the taper design of firebox mortar is not
required.
Installation Tips
*Minimum Duct sizes
Model
Supply Air
Return Air
SBB
8 X 24
8 X 24
* The supply air extended plenum size should be the
same as “Minimum Square inches” shown in above
table for 8-10 feet from furnace, then gradually
reduced to the end of the duct system.
* Use a minimum pipe size of 6 inches in diameter in
runs and in no case smaller than 5 inches in diameter.
* Set blower C.F.M. to obtain 85°F temperature rise
through unit, when fired on oil.
Finally
W
e stress that it is your obligation to see that:
1. Owner receives
A) “Owner’s Operating Instructions”
B) This set of Installation Instructions
2. That installation is made in accordance with C.S.A.
Installation Standard B 139 or the National Building
Code or NBFU No. 31
3. Owner is fully instructed in operating furnace, and in
all procedures necessary to ensure its complete and
safe operation.