![SummerAire SBB Installation And Owner'S Operating Instructions Download Page 13](http://html.mh-extra.com/html/summeraire/sbb/sbb_installation-and-owners-operating-instructions_1391137013.webp)
Specifications for SBB Fur
nace
B.T
.U.
96000
12000
124000
137000
BONNET
*NOZZLE
.85 - 80°
1.00 - 80°
1.10 - 80°
1.20 - 80°
SS/AR
SS/AR
SS/AR
SS/AR
COMBUSTION
SA-1
SA-1
SA-1
SA-1
CHAMBER
AIR
2 - 12 X 24
2 - 12 X 24
2 - 12 X 24
2 - 12 X 24
FILTERS
EXT.
.20”
.20”
.20”
.20”
STATIC
C.F.M.
1025
1200
1325
1450
BLOWER
DELHI TORIN
DELHI TORIN
DELHI TORIN
DELHI TORIN
MAKE
G12 BC
G12 BC
G12 BC
G12 BC
1200 -5
1200 -5
1200 -5
1200 -5
BLOWER
8”
8”
8”
8”
PULLEY
MOTOR
3-1/4X 1/2
3-1/4X 1/2
3-1/4X 1/2
3-1/4X 1/2
PULLEY
TURNS
4-1/2”
3-1/2”
3”
1”
OPEN
MOTOR
1/3
1/3
1/3
1/3
H.P.
BELT
45”
46”
46”
46”
SIZE
BURNER
FAFC - 2
FAFC - 2
FAFC - 3
FAFC - 3
SHIPPING
970
970
970
970
WEIGHT
* Note:
All nozzles ar
e semi solid spray pattern as specified on label
Nozzle shipped in unit is 1.20 - 80° - can be changed within specified ranges for desired output (see above)
WHEN FIRING AT .85G.P.H. (U.S.) OR 1.00 G.P.H. (U.S.) END CONE MUST BE CHANGED TO AFC - 2
Bonnet capacity rating given is for oil side
Maximum output of wood side is approximately 120,000 B.T.U.
“PULLY TURNS OPEN” shown above is a guide ONLY, UNIT IS TO BE ADJUSTED TO GIVE A 85°
TEMPERATURE RISE