RESTARTING BURNER AFTER EXTENDED SHUT DOWN.

The complete oil burner should be checked and serviced by a qualified technician.

•  Check oil pump strainer

•  Replace oil filter cartridge

•  Check electrodes

•  Oil burner motor ( see lubrication section )

•  Restart burner by following instructions in; “STARTING THE OIL BURNER” section.

•  If your furnace has been shut off for an extended period – contact your qualified service technician

 

  for start – up

SUMMER FAN OPERATION

During summer, continuous air circulation can be obtained by pulling / sliding the manual fan switch from 

the “Auto” position to the “On” position

DUAL AIR OPERATION 

This furnace is equipped with a dual ( two ) speed blower system which allows partial air distribution

 

at all times. When the thermostat calls for Heat, the Oil Burner starts and the HIGH speed quickly

 

distributes warm air throughout the home. When the HIGH SPEED stops, the “LOW” speed continues 

operating, circulating the air to even the temperature throughout the house. If the “LOW” speed feature

 

is not required / desired, operate the small “rocker” switch located on the power junction box.

MAINTENANCE

OIL FURNACE ANNUAL SERVICE

The oil burner and furnace should be thoroughly cleaned and serviced annually by a qualified service

 

technician, and where required by law, a licensed technician.

The nozzle should be changed annually - handle nozzle with care so that the inside surface tip is not 

scratched. The electrodes should be cleaned and adjusted (see oil burner manual with the oil burner).

LUBRICATION

Apply 2 – 3 drops of SAE 20 – 30 Non Detergent oil ONLY to the oil port(s) located at either end of the 

burner motor.

Apply 2 – 3 drops of SAE 20 – 30 Non Detergent oil ONLY to the oil ports located at either end of the 

blower motor. 

DO NOT OIL THE FAN BEARINGS!

CAUTION : 

Before cleaning, shut off electrical power supply to the furnace.  

Summary of Contents for OLM SERIES

Page 1: ...LL INSTALLATION INFORMATION _ ______________________________ _____________________________ Installing Contractor Telephone Number _ ______________________________ _____________________________ Unit Model Number Unit Serial Number _________________________________ Installation Date NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE OLM SERIES OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS2C TJERNLUND SID...

Page 2: ...y law a licensed technician shall set up this unit and adjust controls DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD Turn main oil burner switch to OFF Close all oil supply valves The heating system sh...

Page 3: ...ibutes warm air throughout the home When the HIGH SPEED stops the LOW speed continues operating circulating the air to even the temperature throughout the house If the LOW speed feature is not required desired operate the small rocker switch located on the power junction box MAINTENANCE OIL FURNACE ANNUAL SERVICE The oil burner and furnace should be thoroughly cleaned and serviced annually by a qu...

Page 4: ...ILTER This furnace should never be operated without filters A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS Clean or replace filters each heating season or as required Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace are listed below DO NOT SUBSTITUTE Note Changing the type or size of filter used in your Summeraire furnace can serio...

Reviews: