background image

4

CLEANING – OLM SERIES

This furnace shall be cleaned annually. This annual service will identify if damaged or replacement parts 

are necessary.

•  If cleaning is required. The following steps should be taken.

•  Disconnect ( remove ) flue pipe.

•  Remove flue collar panel located at the rear of the furnace.

•  Disconnect the oil line and remove the oil burner from the furnace.

•  Remove baffle from secondary heat exchanger

•  Clean the secondary heat exchanger with a stiff brush and vacuum cleaner suitable for this purpose.

•  Inspect heat exchanger prior to  reassembly

•  After cleaning is complete, replace the flue baffle, collar plate and gaskets with NEW!

•  Replace the oil burner      

•  At the beginning of the heating season, have the complete heating system checked by a qualified

 

  mechanic, and where required by law, a licensed mechanic. 

NOTE:

 WE RECOMMEND THAT A QUALIFIED MECHANIC OR WHERE REQUIRED BY LAW,

 

A LICENCED MECHANIC 

ONLY

 SHOULD PERFORM ALL SERVICE AND CLEANING OF YOUR 

SUMMERAIRE FURNACE ! 

AIR FILTER

This furnace should never be operated without filters.

A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS

Clean or replace filters each heating season, or as required.

Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace,

 

are listed below. 

DO NOT SUBSTITUTE !

Note: Changing the type or size of filter used in your Summeraire furnace can seriously affect the

 

operation of the furnace!

AIR FILTER SPECIFICATIONS

Filter size: 20” X 20” X 1” – CSA or ULC Certified/Approved

Type: Throw-away/disposable

USE OF FILTERS OTHER THAN THOSE SPECIFIED ABOVE, CAN CAUSE DANGEROUS 

ELEVATION OF FURNACE TEMPERATURES – THIS IS AN UNSAFE CONDITION !

DO NOT USE / INSTALL PLEATED TYPE AIR FILTERS IN THIS FURNACE !

WARNING:

 Your furnace requires Combustion Air

 

          

DO NOT

 close off furnace room or enclose furnace - this will starve to furnace oil burner    

                      for air necessary for combustion and could result in a dangerous situation.

NOTE:

IF YOUR SUMMERAIRE FURNACE IS INSTALLED WITH A SS2-C TJERNLUND SIDEWALL  

POWER VENTOR.

IT IS THE USERS / HOMEOWNERS RESPONSIBILITY TO KEEP THE AREA AROUND THE 

VENT TERMINAL FREE OF ICE , SNOW AND DEBRIS !

F-OLM-USMAN-EN-REV2

Summary of Contents for OLM SERIES

Page 1: ...LL INSTALLATION INFORMATION _ ______________________________ _____________________________ Installing Contractor Telephone Number _ ______________________________ _____________________________ Unit Model Number Unit Serial Number _________________________________ Installation Date NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE OLM SERIES OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS2C TJERNLUND SID...

Page 2: ...y law a licensed technician shall set up this unit and adjust controls DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD Turn main oil burner switch to OFF Close all oil supply valves The heating system sh...

Page 3: ...ibutes warm air throughout the home When the HIGH SPEED stops the LOW speed continues operating circulating the air to even the temperature throughout the house If the LOW speed feature is not required desired operate the small rocker switch located on the power junction box MAINTENANCE OIL FURNACE ANNUAL SERVICE The oil burner and furnace should be thoroughly cleaned and serviced annually by a qu...

Page 4: ...ILTER This furnace should never be operated without filters A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS Clean or replace filters each heating season or as required Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace are listed below DO NOT SUBSTITUTE Note Changing the type or size of filter used in your Summeraire furnace can serio...

Reviews: