background image

 

17 

FOR INSTALLERS AND PROFESSIONALS 

 

APPENDIX 1: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL) 

 

 

 
 

Summary of Contents for 100Fi

Page 1: ...Thank you for choosing Full inverter pool heat pump INSTALLATION USER MANUAL ...

Page 2: ......

Page 3: ...e before installation 10 2 2 Installation instruction 11 2 3 Trial after installation 14 2 4 Maintenance and winterizing 14 3 TROUBLE SHOOTING FOR COMMON FAULTS 15 4 FAILURE CODE 16 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 17 APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 18 APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL 19 PLEASE READ IT CAREFULLY AND KEEP IT FOR SUBSEQUENT U...

Page 4: ...se a Any maintenance work on the heat pump must be carried out only by a qualified Service Technician b Do not place put items on the heat pump c Do not block air outlet of the heat pump 2 Installation a This product must be kept away from any source of fire b The installation can t be in a closed environment or indoors and must be kept well ventilated c Vacuum completely before welding any mainte...

Page 5: ... pump during transportation c The product must be kept away from any source of fire d Storage place should be well ventilated 4 Maintenance Notice a For repair or scrap please contact a qualified Service Technician for advice b Qualification requirement Only qualified Service Technicians are permitted to carry any service work on heat pump c Repairing or filling refrigerant R32 may only be carried...

Page 6: ...erating conditions and range ITEMS RANGE Operating range Air temp 7 43 Temp setting heating 18 40 cooling 12 30 The heat pump will have ideal performance in the operation range Air 15 25 1 3 Advantages of different modes The heat pump has two modes Smart and Silence They have different advantages under different conditions ...

Page 7: ...the heat pump to avoid the titanium heat exchanger damage 1 4 3 Don t put obstacles in front of the air inlet and outlet of the heat pump Otherwise heating efficiency will be sharply reduced even stopping the system 1 4 4 Do not put anything into inlet or outlet do not remove fan cover MODE RECOMMENDATION ADVANTAGES Smart mode As standard Heating capacity 20 to 100 capacity Intelligent optimizatio...

Page 8: ...tances occurred e g abnormal noises smells smokes and leakage of electricity switch off the main power immediately and contact your local dealer Do not try to repair the heat pump by yourselves 1 4 7 The main power switch should be out of the reach of Children 1 4 8 Cut off the power in a lightning storm power surges can damage heat pumps ...

Page 9: ... Abnormal outdoor power supply 2 OPERATIONS 2 1 Notice before using 2 1 1 The user is advised to start the water pump before the heat pump and turn off the heat pump before the water pump for long life circle 2 1 2 Check firstly for any water leakage of piping connection then power on press the ON OFF button of the heat pump and set suitable temperature 2 2 Operation instructions ...

Page 10: ... Timer ON OFF 2 2 2 Time setting Press for 5 seconds to enter time setting 88 88 is flashing on the display Press and to adjust the time fast adjusting by continuous pressing Then press to confirm and exit In the time setting mode if no operation for 30 seconds the previous pressing will be lost and exit automatically 2 2 3 Timer on and off Press the for 10 seconds to enter the timer setting The O...

Page 11: ...ost needs to be more than 30 minutes The symbol of defrost is twinkling when machine is compulsory or auto defrost The period and ending of compulsory defrost is the same as auto defrost 2 3 Daily maintenance and winterizing 2 3 1 Daily Maintenance Please don t forget to cut off power supply of the heat pump Please clean the evaporator with household detergents or clean water NEVER use gasoline th...

Page 12: ... 5 5 5 6 8 7 7 9 8 12 1 12 1 16 4 Rated input power kW at air 15 C 0 17 1 2 0 19 1 5 0 22 1 73 0 27 2 2 0 3 2 6 0 38 3 3 0 57 3 8 0 53 3 9 0 62 5 2 Rated input current A at air 15 C 0 74 5 2 0 83 6 5 0 96 7 52 1 17 9 6 1 3 11 3 1 65 14 3 2 48 16 5 0 76 5 6 0 89 7 4 Power supply 230V 1 Ph 50Hz 400V 3 Ph 50Hz Advised water flux m h 2 4 3 4 4 6 5 7 6 5 8 5 8 10 10 12 10 12 12 18 Sound pressure 1m dB ...

Page 13: ...TALLATION AND MAINTENANCE The heat pump must be installed by a professional team The users are not qualified to install by themselves otherwise the heat pump might be damaged and risky for users safety 2 1 Notice before installation 2 1 1 The inlet and outlet water unions can t bear the weight of soft pipes The heat pump must be connected with hard pipes 2 1 2 In order to guarantee the heating eff...

Page 14: ...ND PROFESSIONALS 2 2 Installation instruction 2 2 1 Location and size The heat pump should be installed in a place with good ventilation The picture can t be displayed MINIMUM DISTANCE Filter Water processor Water switch ...

Page 15: ...ecting devices and cable specification Connect to appropriate power supply the voltage should comply with the rated voltage of the products Well earth the heat pump Wiring must be connected by a professional technician according to the circuit diagram Set breaker or fuse according to the local code leakage operating current 30mA The layout of power cable and signal cable should be orderly and not ...

Page 16: ...mmerwave 210Fi Summerwave 270Fi Summerwave 270Fi Summerwave 350Fi Breaker Rated Current A 10 5 12 0 14 5 16 5 18 0 21 0 24 0 9 0 12 0 Rated Residual Action Current mA 30 30 30 30 30 30 30 30 30 Fuse A 10 5 12 0 14 5 16 5 18 0 21 0 24 0 9 0 12 0 Power Cord mm2 3 2 5 3 2 5 3 2 5 3 2 5 3 4 3 4 3 6 5x2 5 5x2 5 Signal cable mm2 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 3 0 5 NOTE The above data i...

Page 17: ...leakage of water Power on and press the ON OFF button of the heat pump and set desired temperature in the thermostat In order to protect the heat pump the heat pump is equipped with start delay function When starting the heat pump the fan will start to run in 3 minutes in another 30 seconds the compressor will start to run After pool heat pump starts up check for any abnormal noise from the heat p...

Page 18: ...he breaker Fan running but with insufficient heating evaporator blocked Remove the obstacles Air outlet blocked Remove the obstacles 3 minutes start delay Wait patiently Display normal but no heating Set temp too low Set proper heating temp 3 minutes start delay Wait patiently If above solutions don t work please contact your installer with detailed information and your model number Don t try to r...

Page 19: ... cooling mode 7 P0 Controller communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp sensor failure 12 P5 Gas return temp sensor failure 13 P6 Cooling coil pipe temp sensor failure 14 P7 Ambient temp sensor failure 15 P8 Cooling plate sensor failure 16 P9 Current sensor failure 17 PA Res...

Page 20: ...17 FOR INSTALLERS AND PROFESSIONALS APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Page 21: ...18 FOR INSTALLERS AND PROFESSIONALS APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Page 22: ...19 FOR INSTALLERS AND PROFESSIONALS APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...

Page 23: ... with filtration clock A Water pump timer B Water pump wiring of Heat Pump Note The installer should connect A parallel with B as above picture To start the water pump condition A or B is connected To stop the water pump both A and B should be disconnected ...

Page 24: ...Thank you for choosing Full inverter Pool heat pump Version Cb9Ir32 ...

Reviews: