13
FOR INSTALLERS AND PROFESSIONALS
1. Wiring diagram
B. For power supply: 400V 50Hz
NOTE:
Must be hard wired, no plug allowed (In Australia, Summerwave 80Fi~ Summerwave 135Fi has
plug for optional).
For your safe use in winter, it’s strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
2. Options for protecting devices and cable specification
MODEL
Summerwave
80Fi
Summerwave
100Fi
Summerwave
135Fi
Summerwave
150Fi
Summerwave
175Fi
Summerwave
210Fi
Summerwave
270Fi
Summerwave
270Fi
Summerwave
350Fi
Breaker
Rated Current
A
10.5
12.0
14.5
16.5
18.0
21.0
24.0
9.0
12.0
Rated Residual
Action Current
mA
30
30
30
30
30
30
30
30
30
Fuse A
10.5
12.0
14.5
16.5
18.0
21.0
24.0
9.0
12.0
Power Cord
(
mm
2
)
3×2.5
3×2.5
3×2.5
3×2.5
3×4
3×4
3×6
5x2.5
5x2.5
Signal cable
(
mm
2
)
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
NOTE: The above data is adapted to power cord ≤ 10m.
If power cord is
>
10m, wire diameter must
be increased. The signal cable can be extended to 50m at most.
A. For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Supply
230V 50Hz
Breaker
Earthing
Fuse
Fuse
Summary of Contents for 100Fi
Page 1: ...Thank you for choosing Full inverter pool heat pump INSTALLATION USER MANUAL ...
Page 2: ......
Page 20: ...17 FOR INSTALLERS AND PROFESSIONALS APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...
Page 21: ...18 FOR INSTALLERS AND PROFESSIONALS APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...
Page 22: ...19 FOR INSTALLERS AND PROFESSIONALS APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...
Page 24: ...Thank you for choosing Full inverter Pool heat pump Version Cb9Ir32 ...