Installation and Operating Instructions
10002 Channel Series
10002_Channel_Series_EN_20201208_V01.docx
12
6. All cutters and spacers must be clean and free from cracks or excessive wear.
7. Shafts should be clean and any burrs filed off for easier stacking. Inspect shafts
for excessive wear of hexagonal portion.
Contact the Sulzer service department if any of the above requires replacement.
Re-assembly advice
1.
Lubricate gears on re-assembly with the specified lubricant.
2.
Re-connect wiring at motor(s) terminal box(es) using tag leads for identification.
3.
Re-open system isolation valves.
4.
On completion of assembly, run
through the ‘initial start-up’ procedure.
Extended shutdown
For extended shutdown refer to the Inspection / Storage section.
Maintenance
For service or parts please contact your Sulzer representative. DO NOT attempt service other than
that described in this section.
Remove and lock out supply power.
After first 3 months, then every 6 months or if solids not processed:
Check cutters
for wear, edges should not be rounded. (See Allowable
wear tolerances.)
Check cutter stack tightness.
If loose or worn, refer to Troubleshooting.
Every 12 months routine maintenance should be carried out.
Check cutter stack tightness and cutters for wear.
Remove drive assembly, then remove top and bottom covers. If top or
bottom seals housings are contaminated with effluent, contact your
local Sulzer service centre.
Prior to refitting top and bottoms covers, fit new gaskets.
Every 5 years:
•
Remove drive assembly, top cover and old grease.
•
Inspect gears for damage or wear, replace if necessary, then replenish
grease (see Lubrication table).