APPLICATION GUIDE
Sulliar encourages its customers to participate in a
fluid analysis program with the fluid suppliers. In
some cases the analysis results suggest a fluid
change interval which differs from the User Manual.
Contact a Sulliar representative for details.
3.8
LUBRICATION CHANGE
RECOMMENDATIONS AND
MAINTENANCE, FLUID
FILTER AND SEPARATOR
NOTE
When performing a fluid change or topping
off the fill, the proper level should be at half
of the sight glass, with the machine off.
Mixing, changing or adding other lubricants
within the compressor unit may void the
air-end warranty.
LUBRICANT
FLUID CHANGE
FLUID FILTER CHANGE
SEPARATOR CHANGE
Sullube
A,E
G,C
A,D
A - 8,000 hours or once per year, whichever comes first.
C - When measured pressure loss exceeds 20 psig (1.3 bar).
D - When measured pressure loss exceeds 10 psig (0.7 bar).
E - When required as the result of fluid analysis or known contamination.
G - Every 2,000 hours.
CAUTION
The use of plastic bowls on line filters and
other plastic airline components without
metal guards can be hazardous. Synthetic
coolants or the additives used in mineral
oils can alter their structural integrity and
create hazardous conditions. Metal bowls
should be used on any pressurized system
for safety concerns.
“The Plastic Pipe Institute recommends
against the use of thermoplastic pipe to
transport compressed air or other com-
pressed gases in exposed above ground
locations, e.g in exposed plant piping.” (I)
Sullube should no be used with PVC piping
systems. It may affect the bond at
cemented joints. Certain other plastic mate-
rials may also be affected.
(I) Plastic Pipe Institute, Recommendation
B, Adopted January 19, 1972.
Summary of Contents for TS20C
Page 10: ...NOTES 10...
Page 13: ...SECTION 2 TS20C USER MANUAL 13 Figure 2 2 Sullair Rotary Screw Air Compressor Air Cooled 200HP...
Page 14: ...TS20C USER MANUAL SECTION 2 14 Figure 2 3 Sullair Rotary Screw Air Compressor Air Cooled 250HP...
Page 23: ...NOTES 23...
Page 64: ...TS20C USER MANUAL SECTION 2 64 Figure 2 22 TS20C SSRV NC SUPV AC WC 02250178 822 R02...
Page 66: ...TS20C USER MANUAL SECTION 2 66 Figure 2 23 TS20C CUST STR SUPV AC WC 02250178 823 R02...
Page 68: ...TS20C USER MANUAL SECTION 2 68 Figure 2 24 TS20C MFV NC SUPV AC RC 02250178 824 R02...
Page 70: ...TS20C USER MANUAL SECTION 2 70 Figure 2 25 TS20C MFV NC SUPV AC VSD FAN 02250178 825 R02...
Page 72: ...NOTES 72...
Page 76: ...SECTION 3 TS20C USER MANUAL 76 Figure 3 2 Identification TS20C Typical 02250175 122 R03...
Page 78: ...TS20C USER MANUAL SECTION 3 78 Figure 3 3 Identification TS2C0 200HP AC 02250175 130 R03...
Page 80: ...TS20C USER MANUAL SECTION 3 80 Figure 3 4 Identification TS20C 250HP AC 02250175 136 R02...
Page 84: ...TS20C USER MANUAL SECTION 3 84 Figure 3 6 Identification TS20C 200HP WCAC SER 02250175 148 R03...
Page 86: ...TS20C USER MANUAL SECTION 3 86 Figure 3 7 Identification V200TS 100 150HP AC 02250182 109 R02...
Page 100: ...NOTES 100...
Page 107: ...SECTION 4 TS20C USER MANUAL 107...
Page 108: ...NOTES 108...
Page 110: ...NOTES 110...
Page 122: ...TS20C USER MANUAL SECTION 7 122...
Page 123: ...NOTES 123...