TS20C USER MANUAL
SECTION 4
104
to Table 4-3: Water Tests.
S
EAWATER
-C
OOLED
U
NITS
Water cleanliness is critical for operation of the
compressor. A strainer must be installed in the inlet
piping of the water system. It is also recommended
that a solenoid valve (normally closed) be installed
into the water outlet side of the compressor system.
Consult the Sulliar Service Department for
assistance in setting up these recommended
precautionary functions. In addition, be aware the
cleaning of coolers as a result of fouling is a
customer responsibility.
The recommended flow rate cannot be exceeded. An
orifice plate must be installed in the pipe-work at
least 3.3 ft (1 m) before the cooler. The orifice size
must be calculated to ensure that the maximum
seawater flow rate cannot be exceeded. Without
these precautions, the seawater flow rate through the
cooler may be several times the recommended
maximum, which will lead to rapid system failure.
No oil cooler manufacturer can guarantee that its
products will have an indefinite life and for this
reason, we suggest that the cooling system be
designed to minimize any damage caused by oil
cooler leaking. This can be achieved as follows:
The oil pressure should be maintained at a pressure
higher that the seawater pressure. In the event of a
leak occurring, the oil will be prevented from
becoming contaminated.
When the hydraulic system is not in use, the coolers
should be isolated from incoming seawater under
pressure.
The seawater outlet pipe from the cooler should have
an open run to waste piping.
Table 4-3: Water Tests
Substances
Test Interval
Acceptable Concentration
Corrosivity Hardiness, pH, Total Dis-
solved Solids, Temperature at inlet,
Alkalinity
Monthly-if stable for 3 to 4 months,
analyze quarterly
Langerlier Index 0 to 1
Iron
Monthly
<2 ppm
Sulphate
Monthly
<50 ppm
Chloride
Monthly
<50 ppm
Nitrate
Monthly
<2 ppm
Silica
Monthly
<100 ppm
Desolated Oxygen
Daily-if stable, analyze weekly
<0 ppm (as low as possible)
Oil & Grease
Monthly
<5 ppm
Ammonia
Monthly
<1 ppm
NOTE
If seawater is to be used for cooling,
optional copper-nickel coolers must be
selected.
Seawater
Pressure
psi (bar)
100/150HP
200/250HP
Orifice size for 80 GPM
orifice diameter in inch
(mm) to give a maximum
seawater flow of
80 GPM (302.8 l/min)
Orifice size for 160 GPM
orifice diameter in inch
(mm) to give a maximum
seawater flow of
160 GPM (605.6 l/min)
25 (1.7)
.95 (24.1)
1.35 (34.3)
35 (2.4)
.88 (22.4)
1.24 (31.5)
45 (3.1)
.82 (20.8)
1.16 (29.5)
55 (3.8)
.78 (19.8)
1.10 (27.9)
65 (4.45)
.75 (19.1)
1.06 (26.9)
75 (5.2)
.72 (18.3)
1.02 (25.9)
Summary of Contents for TS20C
Page 10: ...NOTES 10...
Page 13: ...SECTION 2 TS20C USER MANUAL 13 Figure 2 2 Sullair Rotary Screw Air Compressor Air Cooled 200HP...
Page 14: ...TS20C USER MANUAL SECTION 2 14 Figure 2 3 Sullair Rotary Screw Air Compressor Air Cooled 250HP...
Page 23: ...NOTES 23...
Page 64: ...TS20C USER MANUAL SECTION 2 64 Figure 2 22 TS20C SSRV NC SUPV AC WC 02250178 822 R02...
Page 66: ...TS20C USER MANUAL SECTION 2 66 Figure 2 23 TS20C CUST STR SUPV AC WC 02250178 823 R02...
Page 68: ...TS20C USER MANUAL SECTION 2 68 Figure 2 24 TS20C MFV NC SUPV AC RC 02250178 824 R02...
Page 70: ...TS20C USER MANUAL SECTION 2 70 Figure 2 25 TS20C MFV NC SUPV AC VSD FAN 02250178 825 R02...
Page 72: ...NOTES 72...
Page 76: ...SECTION 3 TS20C USER MANUAL 76 Figure 3 2 Identification TS20C Typical 02250175 122 R03...
Page 78: ...TS20C USER MANUAL SECTION 3 78 Figure 3 3 Identification TS2C0 200HP AC 02250175 130 R03...
Page 80: ...TS20C USER MANUAL SECTION 3 80 Figure 3 4 Identification TS20C 250HP AC 02250175 136 R02...
Page 84: ...TS20C USER MANUAL SECTION 3 84 Figure 3 6 Identification TS20C 200HP WCAC SER 02250175 148 R03...
Page 86: ...TS20C USER MANUAL SECTION 3 86 Figure 3 7 Identification V200TS 100 150HP AC 02250182 109 R02...
Page 100: ...NOTES 100...
Page 107: ...SECTION 4 TS20C USER MANUAL 107...
Page 108: ...NOTES 108...
Page 110: ...NOTES 110...
Page 122: ...TS20C USER MANUAL SECTION 7 122...
Page 123: ...NOTES 123...