SECTION 4
SUPERVISOR CONTROLLER™ USER MANUAL
19
P3 Oil Pressure Low, dP3 Oil
Pressure Low
ALL
ALWAYS
Oil Pressure Low
Oil pump failure, consult Sul-
lair service department.
Oil filter clogged; replace oil
filter.
FLOODED
ALWAYS
Sump oil level low, replenish
oil to proper level.
Low ambient temperature,
sump heater may be
required in ambients below
40°F (4°C).
Oil pump may be required for
remote coolers.
P1 Sensor Fail, P2 Sensor
Fail, P3 Sensor Fail, P4 Sen-
sor Fail, T1 Sensor Fail, T2
Sensor Fail, T3 Sensor Fail,
T4 Sensor Fail, T5 Sensor
Fail
ALL
ALWAYS
Sensor or Wiring Failure
Check sensor wiring.
Check sensor.
dP1 Separator High
FLOODED
ALWAYS
Pressure Across Separa-
tor High
Plugged separator elements,
replace.
Pressure sensor failure,
check sensor wiring.
Factory Setup Error
ALL
ALWAYS
The Factory Setup Infor-
mation Needs to be
Reviewed for Correct Val-
ues
If problem persists replace
Supervisor.
P1 Sump Pressure High
FLOODED
ALWAYS
Sump Pressure High (Pop-
pet, Sullicon, Spiral, Blow-
down or Pneumatic Valve
Failed)
Check valves. Check Sulli-
con adjustment (see Control
Adjustment section in the
compressor operator’s man-
ual).
Solenoid valves, check oper-
ation and wiring.
ALL
ALWAYS
Pressure regulator, check
adjustment and operation.
FLOODED
ALWAYS
Check minimum pressure
check valve (not applicable
to Oil Free compressors).
Table 4-1: Troubleshooting Guide—Supervisor Controller
Message
Model
Enable
Probable Cause
Remedy
Summary of Contents for SUPERVISOR CONTROLLER
Page 8: ...NOTES 6...
Page 15: ...13 NOTES...
Page 16: ...SUPERVISOR CONTROLLER USER MANUAL SECTION 2 14 Table 2 1 Supervisor Controller Menu Tree...
Page 18: ...16 NOTES...
Page 30: ...28 NOTES...
Page 31: ...Section 5 29 SUPERVISOR CONTROLLER USER MANUAL WIRING DIAGRAMS...
Page 51: ...NOTES...