SRL Service Manual
Revision 00
July 2007
Page 52 of 56
10.4.2 Resetting the Alarm History
1) Press
the
Alarm Reset
&
Alarm Report
buttons
simultaneously
to access the User Parameter
Menu. The display will show you are at Parameter “A1”.
2) Press
the
Down
button repeatedly to scroll down to Parameter “B7”
.
3) Press
Enter
to access this parameter. The display will show you it’s value is “no”.
(The value cannot be changed by pressing the Up or Down buttons.)
4) Press
the
Up
&
Enter
buttons
simultaneously
for
5 seconds.
The value will change to “Yes” for
a moment and then change back to “no”. The alarm has now been reset.
5) Press
Exit
to exit the parameter. The display will show you are at Parameter “B7”.
6) Press
Exit
again to exit the User Parameter Menu. The display will show the dewpoint if the dryer
is on, “OFF” if the dryer is off, or “rOF” if the dryer is in Remote Off Mode.
Please Note:
The purpose of the Alarm History Report warning is to provide critical information to service personnel
when troubleshooting the unit.
For this reason, the procedure presented below is intended
ONLY for authorized factory and distributor service technicians.
&
&