Section 5
27
WS CONTROLLER USER INTERFACE MANUAL
TROUBLESHOOTING
5.1
TROUBLESHOOTING
INTRODUCTION
This Troubleshooting section is provided as a guide
to aid in diagnosing and resolving compressor
problems when they occur. The information
contained in Table 5.1, Troubleshooting Guide, has
been compiled from factory experience and contains
symptoms and usual causes for the described
problems. Each Service Reminder, Warning, or
Fault Message is listed with conditions of when the
problem may occur, a probable cause, and a
suggested solution to the problem. DO NOT assume
that these are the only problems that may occur.
This document cannot address every possible
adverse condition that may occur nor does it provide
every solution for the potential troubles listed. All
available data concerning the trouble should be
systematically analyzed before undertaking any
repairs or component replacement procedures.
Always perform a detailed visual inspection when a
machine problem occurs prior to attempting any
repairs. Doing so may avoid unnecessary repair
and/or additional damage to the compressor.
Always remember to:
a.
Check for loose wiring.
b.
Check for damaged piping.
c.
Check for parts damaged by heat or an elec-
trical short circuit, usually apparent by discol-
oration or a burnt odor.
Should your problem persist after making the
recommended check, consult your nearest Sullair
Distributor or the Sullair Corporation factory Service
Department.
5.2
TROUBLESHOOTING GUIDE
Table 5.1 contains symptoms and usual causes for
the problems that may occur throughout the
compressor system. Each warning or fault message
that may appear is listed along with conditions for the
problem, a probable cause, and a suggested solution
to the problem. DO NOT assume that these are the
only troubles that may occur.
NOTE
and
portray com-
mon systematic problems that can occur
during controller operation. For a more
thoroughly in-depth coverage of machine
operation troubles, consult the Trouble-
shooting Section in the machine’s opera-
tor’s manual.
Table 5-1: WS Controller Troubleshooting Guide
MESSAGE
PROBABLE CAUSE
REMEDY
Analyze Fluid
Service interval has expired.
Maintenance due.
Select Maintenance from menu to see
service due and part numbers.
Aux. Motor Overload
Auxiliary Motor Tripped on Cooling
Fan, Fluid Pump or Other Motor.
Reset auxiliary overload after element
cools. Verify correct motor amps.
Check for loose connections.
Check motor starter contact for proper
operation.
Check line voltage, if low consult power
company.