background image

11

10

ENGLISH 

ENGLISH 

Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)

 

 

www.sulion.es

CIF  A28763647

+34 916774540

ATC: 

916749481 - [email protected]  /  

SAT :

 916749483 - [email protected]

Due to the fan’s movement, certain fastenings may become loose. Check all fastenings twice per year at a 

minimum in order to ensure that they are sufficiently tight. If necessary, they must be retightened.

If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar 

qualified personnel in order to avoid any malfunction.

Only suitable for indoors. 

Replaceable bulb / Replaceable LED

  

Replaceable driver

 

Replaceable receiver

Do not throw away electrical products together with household waste. We ask you to recycle the packaging 

at the collection points provided for this purpose. Contact local authorities or your provider for recycling 

advice. Thank you for recycling at the collection points provided for this manual.

Note: 

The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions 

and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be 

included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.

Preparing for installation

Note: 

The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully 

separate the fan’s parts, avoiding the use of cutters or blades that could scratch any part of it.

Device technical spectifications

Remote control

Syncing the receiver and the remote control for fan operation

If the receiver and transmitter of this fan are properly synchronized, the fan will work. During synchronization the receiver 

recognizes the signal from the transmitter, this is called the learning process.

Make sure the fan is disconnected. This is essential for the synchronization process.

Unless the synchronization process has been successful, the fan will work partially or will not work. By default, all fans have 

been preconfigured at the factory and should be functional once the installation is completed and the fan is turned on.

If the remote control does not work after installation or during use, synchronization can be performed as indicated below. Note 

in any case that there could be other reasons why your fan or remote control does not work:

  Make sure all connections are correctly made.

  Make sure that the remote control contains batteries.

  Make sure that all switches (main and isolation) are on.

Instructions for synchronizing the receiver and the remote control

The control of this fan does not require synchronization with the recelver, the control is already factory-linked with its receiver; 

Universal mode and Unit mode:

- Unit Mode:

This type of synchronization allows you to control two or more nearby fans independently, each with its remote control.

Synchronization:

The control of this fan does not require synchronization with the receiver, the control is already factory-linked with its receiver

- Universal Mode:

This type of synchronization allows you to control one or more nearby fans with the same remote control.

Synchronization:

1.-Connect the power (wall switch) of the fan or fans that you want to control, and then just within the following

15 seconds, press the key      of the remote control for 5 continuous seconds.

2.-A “beep” sound indicates that the connection has been executed and the equipment can function normally.

3.-Now, transmitter and receiver of the fan / s will have been synchronized. Turn off the fan / s current using the

switch or automatic and then turn it back on / s, this step is the one that closes the synchronization process.

It is not possible for a controller to forget a fan once it has been linked, if you want a fan to leave

to obey a command, another one must be linked to “overwrite it”.

Remote control safety functions

Blocking protection

The remote receiver includes a function that automatically blocks motor operation, cutting current to the motor 30 seconds 

after detecting an obstruction in front of the fan that prevents normal operation. When this happens, you must remove the 

obstacles blocking the fan. Then, press the off button on the remote control to reset the receiver. Now you can continue to 

use the fan normally.

Note: 

Unless you remove the obstruction blocking the fan, it will not operate correctly.

Overload prtection

If the fan’s receiver detects that the motor is operating at greater than 80W (this indicates an overload), current to the motor 

will be cut automatically, which will immediately stop the fan. To reset the receiver, press the off button on the remote control.

Note:  

If the receiver goes into protection mode again, this may indicate a motor defect. Contact the supplier immediately. The 

duration of the warranty is indicated in the warranty document provided in this manual.

Nominal voltage and frequency

220-240V~AC 50/60Hz

Light wattage

24W

Luminous flux

2000lm

Light color temperature

3000/4500/6000K

Nº of light ON/OFF cycles

10000

Nº of hours of light lifespan

30000h

Protection category

Class I

Protection index

IP20

Word temperature

 45ºC

Dimmable/Not dimmable

No dimmable

Maximun ceiling slope on which it can be installed

15º

Light angle

170º

Light Ra

80

Weight

6,3 Kg

This product have a light source of energy efficiency class 

F

Speed

1

2

3

4

5

6

Fan power (W)

7,2

10

12,5

16

25

38

Fan RPM

110

130

150

170

190

230

Fan airflow (m³/h)

75

95

117

137

154

192

Noise level (dB)

15

20

30

35

40

50

Service value SV ((m³ / min) / W)

10,7

7,9

6,8

5,7

4,4

3,8

Power consumption in standby mode (W)

<0,5

Service value measurement standard

EN 62879:2020

FAN

OFF

*After pressing the button         don’t press any other.
The light will be off for 2 hours, then it will turn
on for 5 minutes, will turn for another 2 hours.
This way it will seem as if there is someone at home

.

FAN

OFF

Summary of Contents for 075758

Page 1: ...so a v deos instrucciones y una gu a de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 91674...

Page 2: ...alta de experiencia o conocimiento si se les ha dado la supervisi n o formaci n apropiadas respecto al uso del aparato de una manera segura y comprenden los peligros que implican Los ni os no deben ju...

Page 3: ...ceptor Modo Universal Este tipo de sincronizaci n le permite controlar uno o m s ventiladores pr ximos con el mismo control remoto Sincronizaci n 1 Conectar la corriente interruptor de la pared del lo...

Page 4: ...tando la alimentaci n el ctrica al aparato Verificar el estado de fusibles e interruptores del circuito de alimen taci n de la instalaci n al aparato B Las conexiones de cableado a la instalaci n no e...

Page 5: ...plir el uso al que est destinado el titular de la garant a tendr derecho a la sustituci n del objeto adquirido por otro de id nticas caracter sticas o la devoluci n del precio pagado T rminos y condic...

Page 6: ...ronization allows you to control two or more nearby fans independently each with its remote control Synchronization The control of this fan does not require synchronization with the receiver the contr...

Page 7: ...that wiring connections have been done correctly They must be carried out by a certified electrician C The remote control is unresponsive Replace the remote control battery if necessary Otherwise resy...

Page 8: ...efficacit nerg tique Ce ventilateur fonctionne en courant continu DC ce qui lui permet d tre d une grande efficacit nerg tique tout en produisant un grand volume de circulation d air de mani re silenc...

Page 9: ...t l commande ne fonctionne pas Assurez vous que toutes les connexions sont correctement effectu es Assurez vous que la t l commande contient des piles Assurez vous que tous les interrupteurs principa...

Page 10: ...lation de l appareil B Le raccordement de l appareil n est pas correctement effectu V rifiez que le raccordement est correctement r alis Il doit tre effectu par un lectricien agr C Il ne r pond pas la...

Page 11: ...se s engage r parer gratuitement et totalement les d fauts caus s et les dommages et pr judices occasionnn s directement par ceux ci De m me si la r paration n est pas satisfaisante et l objetnerempli...

Page 12: ...u durante o uso a sincroniza o pode ser realizada conforme indicado abaixo Note em qualquer caso que poderia haver outras raz es pelas quais seu ventilador ou controle remoto n o funciona Verifique se...

Page 13: ...instala o at ao aparelho B As liga es dos cabos da instala o n o est o devidamente aper tadas Comprovar que as liga es dos cabos est o corretas Estas devem ser realizadas por um eletricista especializ...

Page 14: ...s caracter sticas ou a devolu o do pre p que pagou Termos e condi es de garant a www sulion es Gratulation zu Ihrem Kauf Herzlichen Gl ckwunsch zum Kauf der neuesten energieeffizienten Deckenventilato...

Page 15: ...f hrt werden Beachten Sie in jedem Fall dass es andere Gr nde geben kann warum Ihr L fter oder Ihre Fer nbedienung nicht funktioniert Stellen Sie sicher dass alle Verbindungen korrekt hergestellt wurd...

Page 16: ...n Sie ob die Verkabelung korrekt ausgef hrt wurde Sie muss von einer Elektrofachkraft durchgef hrt werden C Die Fernbedienung reagiert nicht Ersetzen Sie gegebenenfalls die Batterie der Fernbedienung...

Page 17: ...ein neues Ger t von identischen Eigenschaften oder die Erstattung des Kaufpreises verlangen Allgemeine Bedingungen f r die Gew hrleistung www sulion es Complimenti per l acquisto Congratulazioni per...

Page 18: ...per cui il tuo ventilatore o telecomando non funziona Assicurarsi che tutte le connessioni siano state eseguite correttamente Assicurarsi che il telecomando contenga batterie Assicurarsi che tutti gl...

Page 19: ...l dispositivo stato disconnesso dalla rete elettrica Controlla i fusibili e gli interruttori sul circuito di installazione del dispo sitivo B I cavi del sistema non sono collegati adeguatamente Contro...

Page 20: ...iti non strette in maniera adeguata o pale deformate in seguito a una pulizia troppo vigorosa pu causare rumore eccessivo e oscillazioni che non saranno coperte della garanzia Eseguendo una manutenzio...

Page 21: ...in bereinstimmungmitdenfolgendeneurop ischen Normen hergestellt wurden DECLARACI N DE CONFORMIDAD CE DECLARATION OF CONFORMITY D CLARATION DE CONFORMIT CE DECLARA O DE CONFORMIDADE CE EU Konformit tse...

Page 22: ......

Reviews: